Chapter 3    Specifications and Functions
 
3.3.3 Details of output signals (PLC CPU 
 QD77MS) 
The ON/OFF timing and conditions of the output signals are shown below. 
(1) QD77MS2/QD77MS4 
 
Device No. 
Signal name 
Details 
Y0 PLC 
READY 
OFF: 
 
PLC READY OFF 
ON: 
PLC READY ON 
(a) This signal notifies the Simple Motion module that the PLC CPU 
is normal.   
• It is turned ON/OFF with the sequence program. 
• The PLC READY signal is turned ON during positioning control, 
OPR control, JOG operation, inching operation, manual pulse 
generator operation and speed-torque control ,etc. unless the 
system is in the GX Works2 test function. 
(b) When the data (parameter etc.) are changed, this signal is turned 
OFF depending on the parameter (Refer to Chapter 7.). 
(c) The following processes are carried out when this signal turns 
from OFF to ON. 
• The parameter setting range is checked. 
• The READY signal [X0] turns ON. 
(d) The following processes are carried out when this signal turns 
from ON to OFF. 
In these cases, the OFF time should be set to 100ms or more. 
• The READY signal [X0] turns OFF. 
• The operating axis stops. 
• The M code ON signal [X4 to X7] for each axis turns OFF, and 
"0" is stored in "[Md.25] Valid M code". 
(e) When parameters or positioning data (No. 1 to 600) are written 
from the GX Works2 or PLC CPU to the flash ROM, this signal 
will turn OFF. 
Y1 
All axis servo ON 
OFF: 
Servo OFF 
ON: 
Servo ON 
• The servo for all the servo amplifiers connected to the Simple 
Motion module is turned ON or OFF. 
Y4 
Y5 
Y6 
Y7 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
Axis stop 
OFF: 
Axis stop not 
requested 
ON: 
Axis stop requested
• When the axis stop signal turns ON, the OPR control, positioning 
control, JOG operation, inching operation, manual pulse generator 
operation and speed-torque control etc. will stop. 
• By turning the axis stop signal ON during positioning operation, the 
positioning operation will be "stopped". 
• Whether to decelerate stop or suddenly stop can be selected with 
"[Pr.39] Stop group 3 sudden stop selection". 
• During interpolation control of the positioning operation, if the axis 
stop signal of any axis turns ON, all axes in the interpolation control 
will decelerate and stop. 
Y8 
Y9 
YA 
YB 
YC 
YD 
YE 
YF 
Axis 1 
Axis 1 
Axis 2 
Axis 2 
Axis 3 
Axis 3 
Axis 4 
Axis 4 
Forward run JOG start 
Reverse run JOG start 
Forward run JOG start 
Reverse run JOG start 
Forward run JOG start 
Reverse run JOG start 
Forward run JOG start 
Reverse run JOG start 
OFF: 
JOG not started 
ON: 
JOG started 
• When the JOG start signal is ON, JOG operation will be carried out 
at the "[Cd.17] JOG speed". When the JOG start signal turns OFF, 
the operation will decelerate and stop. 
• When inching movement amount is set, the designated movement 
amount is output for one operation cycle and then the operation 
stops. 
Y10 
Y11 
Y12 
Y13 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
Positioning start 
OFF: 
Positioning start not 
requested 
ON: 
Positioning start 
requested 
• OPR operation or positioning operation is started. 
• The positioning start signal is valid at the rising edge, and the 
operation is started. 
• When this signal turns ON during BUSY, the warning "Start during 
operation" (warning code: 100) will occur. 
Y14 
Y15 
Y16 
Y17 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
Execution prohibition 
flag 
OFF:  
Not during execution 
prohibition 
ON:  
During execution 
prohibition 
• If the execution prohibition flag is ON when the positioning start 
signal turns ON, positioning control does not start until the 
execution prohibition flag turns OFF. 
Used with the "Pre-reading start function". (Refer to Section 
13.7.7.)