Chapter 11    Manual Control
 
11.3.4 Creating a program to enable/disable the inching operation 
A sequence program must be created to execute an inching operation. Consider the 
"required control data setting", "start conditions", and "start time chart" when creating 
the program. 
The following shows an example when an inching operation is started for axis 1. (The 
example shows the inching operation when a "10.0 µm" is set in "[Cd.16] Inching 
movement amount".) 
 
  Required control data setting 
 
The control data shown below must be set to execute an inching operation. The 
setting is carried out with the sequence program. 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
QD77MS2 
QD77MS4 
QD77MS16
[Cd.16] 
Inching movement 
amount 
100 
Set the setting value so that the JOG speed 
limit value is not increased larger than the 
maximum output pulse 
1517+100n 4317+100n
 
n: Axis No.-1 
 
: Refer to Section 5.7 "List of control data" for information on setting details. 
 
 Start conditions 
 
The following conditions must be fulfilled when starting. The required conditions 
must also be assembled in the sequence program, and the sequence program 
must be configured so the operation will not start if the conditions are not fulfilled. 
 
Signal name 
Signal state 
Device 
QD77MS2 
QD77MS4 
QD77MS16 
Interface 
signal 
PLC READY signal 
ON PLC CPU preparation completed
Y0 
READY signal 
ON QD77MS preparation completed
X0 
All axis servo ON 
ON All axis servo ON 
Y1 
Synchronization flag   ON
Accessible to QD77MS buffer 
memory 
X1 
Axis stop signal 
OFF Axis stop signal is OFF 
Y4 to Y7  [Cd.180] Axis stop
Start complete signal 
OFF Start complete signal is OFF 
X10 to X13  [Md.31] Status: b14
BUSY signal 
OFF QD77MS is not operating 
XC to XF 
X10 to X1F 
Positioning complete 
signal 
OFF
Positioning complete signal is 
OFF 
X14 to X17  [Md.31] Status: b15
Error detection signal 
OFF There is no error 
X8 to XB  [Md.31] Status: b13
M code ON signal 
OFF M code ON signal is OFF 
X4 to X7  [Md.31] Status: b12
External 
signal 
Forced stop input signal 
ON There is no forced stop input 
– 
Stop signal 
OFF Stop signal is OFF 
– 
Upper limit (FLS) 
ON Within limit range 
– 
Lower limit (RLS) 
ON Within limit range 
– 
 
: If the PLC CPU is set to the asynchronous mode in the synchronization setting, this must be 
inserted in the program for interlocking. If it is set to the synchronous mode, it must not be 
inserted in the program for interlocking because it is turned ON when the PLC CPU executes 
calculation.