Справочник Пользователя для Mitsubishi Electronics QD77MS4

Скачать
Страница из 1038
 
 
15- 2 
Chapter 15  Dedicated Instructions
 
15.1 List of dedicated instructions 
The dedicated instructions explained in this Chapter are listed in Table 15.1. 
 
Table 15.1 List of dedicated instructions 
 
Application 
Dedicated 
instruction 
Outline of functions 
Reference
Positioning start 
ZP.PSTRT1 
This function starts the positioning control of the designated 
axis of the Simple Motion module. 
Section 15.3
ZP.PSTRT2 
ZP.PSTRT3 
ZP.PSTRT4 
Teaching 
ZP.TEACH1 
This function carries out teaching the designated axis of the 
Simple Motion module. 
Section 15.4
ZP.TEACH2 
ZP.TEACH3 
ZP.TEACH4 
Writing to flash ROM 
ZP.PFWRT 
This function writes the buffer memory parameters, 
positioning data and block start data to the flash ROM. 
Section 15.5
Parameter initialization 
ZP.PINIT 
This function initializes the buffer memory and flash ROM 
setting data to the factory-set data (initial values of the 
Simple Motion module). 
Section 15.6
 
 
POINT 
 
The dedicated instructions of QD77MS16 can be used for only axis 1 to 4. They 
cannot be used for axis 5 to 16. If the ZP.PSTRT5 to ZP.PSTRT16 or ZP.TEACH5 
to ZP.TEACH16 is executed, the error "Program code error" (error code: 4002) for 
PLC CPU and the error "PLC CPU error" (error code: 803) for QD77MS16 will 
occur and positioning cannot be started. 
Refer to "QCPU User's Manual (Hardware Design, Maintenance and Inspection) for 
error of PLC CPU". 
 
 
15.2 Interlock during dedicated instruction is executed 
The positioning start instruction (ZP.PSTRT ) and teaching instruction (ZP.TEACH ) 
cannot be executed simultaneously in each axis. If they are executed at the same time, 
the second and later instructions are ignored by an internal interlock (no error will 
occur). 
The timing of the positioning start instruction (ZP.PSTRT ) is as shown below. 
 
ZP.PSTRT     instruction ON
Interlock provided by PLC CPU
BUSY signal
Positioning completed signal
OFF
OFF
OFF
OFF
ON
ON
ON
ON