7.0  SPECIFICATIONS
ELECTRICAL
Input Voltage (50/60 Hz):
Standard
Version
24, 120, 230 VAC
VS Version
120, 230 VAC
Power Consumption (excluding PTZ):
Standard
Version
6 watts
VS version
6 watts
P/T Output Voltages:
Standard
Version
24, 120, 230 VAC
VS Version
12 VDC PWM at 15 KHz
P/T Output Currents:
Standard
Version
1.5 amps per motor
VS version
3 amps per motor
P/T Output Power:
Standard
Version
50 watts
VS version
35 watts
Camera Output Voltages:
All Versions
24, 120, 230 VAC
Lens Output Voltages:
All Versions
0 to 12 VDC
Control Method:
CX9500
Coaxitron VIS
CX9504
4-wire RS-485
Standard Baud Rates:
CX9500
1 MHz
CX9504
2400 baud
Command Error Rates:
Duplex
0%
Simplex
0.02%
Input Video Level:
All versions
0.5 to 1.5 V p-p
Input Video Format:
Standard
NTSC, RS-170
Optional
PAL
Video Bandwidth:
All versions
10 MHz
Operating Distances:
Coaxitron
Version
2,000 ft (610 m) on RG-11
RS-485 Version 4,000 ft (1,219 m) on 24 Awg-TP
NOTE: 
All standard baud rates from
600 to 19.2K are available on an op-
tional basis. Please consult the fac-
tory.
NOTE:
 Operating distances given
here are calculated, and based on
typical performance. The actual cal-
culations are explained in the Instal-
lation section of this manual, and
should be done for each application
prior to installation.