3.5  ADJUSTMENTS
To adjust the pan/tilt limits, perform the following steps. Refer to Figure 6 for limit
stop locations.
1.
Factory pan limits are set to 0-355° and tilt limits at ±45°. Pan to the right using
the joystick control until the desired RIGHT pan limit is reached.
2.
Adjust the pan limit stop until the actuator clicks. Lock the limit into position.
3.
Pan to the desired left position, adjust the pan limit stop until the actuator
clicks, and lock into position.
4.
Pan to the left and right to verify exact positioning and tighten both stops se-
curely.
5.
Remove the left cover plate by removing the two screws for access to the tilt
limit stops.
6.
Loosen the screws and move the DOWN limit stop to the furthest position.
Using the joystick control, tilt the unit to the desired down position.
7.
Move the DOWN limit stop until the actuator clicks. Lock the limit into position.
8.
Adjust the UP limit stop in the same way.
9.
Tilt up and down to verify exact positioning and tighten both stops securely.
CAUTION: 
  Do not at-
tempt to adjust limit stops
when pan/tilt is in opera-
tion. Damage to the equip-
ment can result. Also, do
not operate equipment
without limit stops. Do not
remove or reposition fixed
limit stop on the PT280-
24P pan/tilt. DAMAGE
WILL OCCUR.