Справочник Пользователя для Pelco SS3000

Скачать
Страница из 16
PELCO Manual C428M-B (2/98)
5
3.0  INSTALLATION
Save the shipping carton and plastic packing in case the unit has to be returned for
credit or repair.
3.1  CONDUCTOR AND CABLE REQUIREMENTS
Before installing the pan and tilt, determine the conductor requirements and length
of cable you will need to run based on the following:
Conductor requirements for the pan and tilt are as listed below, plus coax cable:
Pan/Tilt
Lens
Cam AC
PT280-24P/PT280-24SL
5+ grnd
4
2
PT280-24P/PP
9+ grnd
8
2
PT280-24SL/PP
10+ grnd
8
2
(Camera power, lens functions and video are fed through the input connector
on the base of the pan/tilt.)
The following are the cable requirements for the PT280 series pan and tilts:
5 Conductor
6 Conductor*
20 Awg
110 ft (33.53m)
210 ft (64.01m)
18 Awg
180 ft (54.86m)
330 ft (100.58m)
16 Awg
290 ft (88.39m)
530 ft (161.54m)
*  Using 2 wire common
3.2  WIRING INSTRUCTIONS
To install and test the pan/tilt you will need to assemble the connector parts pro-
vided. Refer to Section 3.3 for connector assembly.
The PT280 series pan/tilts are prewired for all control functions (pan/tilt, motorized
zoom lens, 24 VAC camera power, and video. All connections are made at the input
connector, eliminating the need for wiring harnesses made in the field. When using
Coaxitron Control Systems, consider using the C1906, C1906/PP, C1925 or C1925/
PP factory assembled pretested cables which are wired for inverted applications.
Wire the control cable per the wiring diagram provided in the PT280 Series Pan/Tilt
manual, C324M, for the specific pan/tilt you are using. (The PT280-24P basic pan/
tilt wiring diagram is included in this manual for reference only.)
NOTE:  
If you are not using the
C1906, C1906/PP, C1925, or C1925/
PP pretested cable you must reverse
the left/right and up/down function
pins as shown in Figure 1.