Справочник Пользователя для Pelco TXB-AD

Скачать
Страница из 32
 
C1492M-I (8/05)
17
 
 EXSITE EXPLOSIONPROOF SYSTEM SETTINGS
 
1. Check wiring to controller.
2. Verify that all SW3 switches on the ExSite system are set to the OFF position.
 
For American Dynamics controllers with only 32 presets:
 
 Set SW3-1 to the ON 
position. Refer to Figure 13 for switch location.
 
3. Set the address for the ExSite system. Refer to Table B and Table D in the 
 
Appendix
 
 for switch 
settings.
4. Attach the pan and tilt unit to the power module. Refer to Figure 11 and Figure 12 and to the 
following:
a.
Align the pan and tilt unit with the power module. Carefully begin to hand-tighten the 
locking ring onto the threads of the power module.
b.
Continue to tighten the locking ring with a spanner wrench.
c.
Tighten the setscrew in the locking ring with a 2 mm Allen wrench.
 
NOTE:
 
  Refer to the installation manual supplied with the ExSite system for instructions on attach-
ing the pan and tilt unit to the power module.
5. Apply power to the system. The following message is displayed on the monitor once the 
configuration cycle is completed:
TXB-AD Rev x.xx
 
NOTE:
 
  x.xx represents the current firmware version.
 
From AD Controller
To Wire Harness
 
B
RX+ (Red)
W
RX- (Green)