Parapet Corner Mount
®
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1.
Installation and servicing should only be done by qualified service personnel and conform
to all local codes.
2.
Installation shall be done in accordance with all local and national electrical and mechanical
codes utilizing only approved materials.
3.
Use only installation methods and materials capable of supporting four times the maximum
specified load.
4.
Use stainless steel hardware to fasten the mount to outdoor surfaces.
5.
To prevent damage from water leakage when installing a mount outdoors on a roof or wall,
apply sealant around the bolt holes between the mount and mounting surface.
Please thoroughly familiarize yourself with the information in this manual prior to installation and
operation.
3500 Pelco Way,
Clovis, CA 93612-5699
USA
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
International Customers:
Tel +1 (559) 292-1981
FAX +1 (559) 348-1120
www.pelco.com
DESCRIPTION
The PP300 and PP301 Parapet Corner Mounts are designed to eliminate the expense and haz-
ards of installing and servicing equipment that is to be mounted on the corners of rooftops and
parapets.
The PP300 mounts on top of rooftops and parapets. The PP301 mounts to the inside of para-
pets. Both mounts rotate 360 degrees in the horizontal plane, allowing equipment to be installed
or serviced from the rooftop easily and safely.
When using the PP300 or PP301 with a ED27/ED2720 or ED28/ED2820 Series Dome, the addi-
tion of the PPI200 Vertical Indexer is required. This will allow vertical rotation of the dome to ac-
quire the clearance needed to swing the boom of the mount over the roof, providing easy and
safe installation and serviceability.
When using the PP300 and PP301 to install equipment such as pan/tilts, a PA2010 or PA2000 is
required. In addition, a PM102A is required if mounting a PT175-24P Pan/Tilt.
INSTALLATION
The PP300/PP301 Parapet Corner Mount kit contains the following items:
Qty
Description
1
Strut pipe (ST1)
1
Corner parapet wall bracket
2
5/16-18 nuts
2
5/16-18 x 2-inch carriage bolts
2
5/16 split lock washers
4
1/4-20 nuts
4
1/4-inch split lock washers
4
1/4-20 x 5/8-inch bolt
Right and left sideplates to turret base:
Qty
Description
20
1/4-inch split lock washers
20
1/4-20 nuts
Installing the Mount
To install the PP300/PP301 Parapet Corner Mount, perform the following steps.
1.
Attach right and left sideplates to turret base using 1/4-inch split lock washers and 1/4-20
nuts provided.
WARNING:
  The
PP300/301 should be
securely mounted to the
structure in accordance with ap-
plicable codes before installing
pan/tilt, etc. The twelve fasteners
to secure the PP300/PP301 to the
rooftop/parapet wall (such as lag
screws or concrete fasteners) are
not supplied. Minimum 3/8-inch
diameter fasteners are recom-
mended; 1/4-inch minimum for
corner wall bracket. Make certain
the mounting surface is able to
support the combined weight of
the mount and camera/enclosure.