PXM100 PEDESTAL MOUNT
 
The PXM100 mount is designed to make the installation and removal of the ExSite power module quick and easy. To install the PXM100 refer to 
Figure 4 and perform the following steps:
1. Attach the power module of the ExSite system to the pedestal mount with four M10 x 16 mm stainless steel bolts and lock washers 
supplied with the power module (refer to Figure 4). Tighten the bolts to 25 to 27 ft-lb (34 to 37 Nm). 
 
Figure 4.  
 
Attach Power Module to PXM100 
 
2. Attach the pedestal mount to the mounting surface with the appropriate hardware (not supplied).
3. Complete the ExSite system installation following the instructions supplied with the equipment.
NOTE:  Figure 4 shows the power module 
being installed on a PXM100 pedestal mount 
(not supplied).