Справочник Пользователя для Pelco IV IP

Скачать
Страница из 28
C3444M-A (7/09)
25
Help Page
Online Help documents the basic instructions for configuring the dome system. Click the Help hyperlink in 
the navigation bar to access these instructions.
Log Off
To log off, click the Log Off button in the navigation bar. A login dialog box appears.
Troubleshooting
If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 
(USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number 
available when calling.
Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel.
Table B.  Troubleshooting the Spectra IV IP Dome System (1 of 2)
Problem
Possible Cause
Suggested Remedy
No video
Power issue (24 VAC)
Verify the 24 VAC power supply connection.
Network connectivity issues
Verify network cable connections.
Replace the network cable with a new cable.
Defective dome system
Use a service connector to verify dome operation. 
Connect one end of the service connector to the 
BNC of the back box. Then connect the other end of 
the service connector to a monitor.
Replace the dome drive.
Image flickering
Flickerless setting
Verify power supply specifications.
Replace the camera module with a new camera.
Image quality
Image not focused
Adjust the field of view and the focus. 
15 ips quality bad
In some networks with high latency, the maximum 
frame rate may not be attainable.
30 ips not available
The IP camera only supports MJPEG up to 15 ips for 
NTSC camera modules, where applicable. For PAL 
camera modules, the maximum rate is 12 ips.
UTP wires are incorrectly 
installed.
Verify that the UTP cable is wired correctly to the 
UTP connector on the back box circuit board. The 
blue wire should be connected to the positive 
terminal, and the gray wire should be connected to 
the negative terminal. Refer to the installation 
manual shipped with the TXB-IP.
No dual 
streams 
Web browser
Not available with Web browser. Only supported by 
the Endura system or Pelco’s API Interface solution.
Cannot record a 
MJPEG stream 
Web browser
Not available with Web browser. Only supported by 
the Endura system or Pelco’s API Interface solution.