Camera Installation and Camera Adjustment
NOTE: When installing the camera, always touch the metal on the chassis first to avoid static electricity damage.
1. Plug the two camera connection leads from inside the monitor into the connectors on the camera. (The connectors are different sizes and 
will only connect in the correct position.)
2. Attach the camera using three spacers and three screws (14 mm). Do not overtighten the screws or the spacers will collapse. The focus 
knobs need to be positioned as shown in Figure 4.
3. Tuck the camera leads neatly into the monitor.
4. Verify the video on the monitor. If satisfactory, close the door and hand-tighten the thumbscrew. If unsatisfactory, go to step 5.
5. The camera focus and zoom can be adjusted on the camera located inside the monitor.
To adjust the camera zoom and focus, first loosen the zoom and focus knobs by turning them counterclockwise. Adjust the zoom and focus 
by sliding the knobs in the appropriate direction. Then lightly tighten the knobs by turning them clockwise to lock the  adjustments (refer to 
Figure 4).
Figure 4. Adjusting the Camera
6. Close the door and hand-tighten the door thumbscrew.
FOCUS KNOB
ZOOM KNOB