Справочник Пользователя для Pelco C1005M-G

Скачать
Страница из 12
C1005M-G (10/02)
3
INSTALLATION
NOTE:  The information in this manual is for PIM software version 4.02 and above.
INSTALLATION FOR INTER-CHECK
Refer to the ICI1000S Inter-Check manual as you install the ICI1000PIM.
1. Configure DIP switch bank 1 on the PIM (refer to 
Configuring DIP Switch Bank 1 section).
2. Configure DIP switch bank 2 on the PIM (refer to 
Configuring DIP Switch Bank 2 section).
3. Locate the 16-pin connector on your register/interface. Plug the register/interface connector into the PIM.
4. Plug one data cable connector into the data connector in the PIM.
5. Connect the other end of the data cable in one of the following ways.
a.
If the Inter-Check and the PIM are within 6 feet (1.8 m) of each other, modify the cable as follows:
Refer to Figure 1 and slit the jacket to expose the wires.
Cut the red and green wires. To ensure the cut wires will not contact each other, either remove a section of the red
and green wires or, in case you want to reconnect the wires later, tape one end of the cut wires.
Plug the cable into the Inter-Check.
b.
If the Inter-Check
  
and the PIM are more than 6 feet (1.8 m) apart, you must use the wiring kit. Refer to Figure 2. The
wiring kit is supplied with the ICI1000SE and ICI1000SI.
6. Mount the PIM inside or near the cash register or other device. Depending on the application, you may need to use
double-sided tape to secure the ICI1000PIM to the mount location.
7. Power-up the Inter-Check. To set all Inter-Check communication parameters to the specific values needed to communicate
with the ICI1000PIM module, do the following:
a.
Enter the main screen by pressing the ESC key and then the ENT key on the keypad.
b.
Once the main screen is present, press the #6 key selection (Diagnostics) and then the #8 key ([DL] PIM Default
Load).
c.
Press the #8 key until the loaded message appears on the screen, and then press the ESC key until the unit is
reinitialized.
(Refer to the C1000M-B manual if more detailed information on this procedure
is required.)
8.  Power-up the register or other device.
9. Connect the power plug into the PIM and plug the wall mount transformer into
power. This will power up the PIM.
10. Upon PIM power up, you should see a prompt that matches your register/
interface type displayed on the monitor. A PIM version number will also be
displayed. If this prompt appears on the monitor, the Inter-Check and the PIM
are communicating properly.
SLIT JACKET TO
EXPOSE WIRES
CUT RED AND 
GREEN WIRES
Figure 1.  Cable Modification