Справочник Пользователя для SECO-LARM USA E-37EV

Скачать
Страница из 8
ENFORCER E-37EV Alarm Pager System
 
 
SECO-LARM U.S.A., Inc.                                                                                       7 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SECO-LARM U.S.A., Inc.                                                                                                   
               33                                              7                                                                                         
 
 
Warning 
 
Ensure that an antenna is connected before connecting power to the unit. Failure to do so may 
damage the transmitter. 
 
Do not open the receiver or transmitter cases. All adjustments have been made at the factory. 
There are no user serviceable parts inside. 
 
Holes marked 1, 2, and 3 on the transmitter case are factory set. Do not make any 
adjustments in these holes. 
 
Use only AAA size 1.5V alkaline batteries for the receiver. 
 
Alarm Paging 
 
When triggered by either the purple (+), green (-), or blue (-) triggers, the receiver will beep 
(or vibrate) continuously for 1 minute in groups of 9. 
 
The Page LED will indicate which transmitter is sending the signal (Green, Red, or Orange). 
 
The Zone LED will indicate which trigger was triggered. 
-  Positive trigger (purple wire) will flash green. 
-  Negative trigger #1 (green wire) will flash red. 
-  Negative trigger #2 (blue wire) will flash orange. 
 
Press the 
ON
/      /OFF button after 30 seconds to stop the indicator. 
Receiver Power-On 
 
The receiver will beep (or vibrate) once each time the receiver is turned on. 
Unattended Indicator 
 
The receiver will beep (or vibrate) once every 30 seconds to remind the user that it received 
a page signal from the transmitter. 
 
Press the 
ON
/      /OFF button to stop the indicator. 
Low-Battery Indicator 
 
The receiver will beep (or vibrate) twice following power-on if the batteries are low. 
 
The receiver will also beep (or vibrate) twice every 60 seconds when the batteries are low. 
Viewing the Page Memory 
 
Scroll back the page signal memory by pressing the 
ON
/      /OFF button repeatedly. 
 
The receiver remembers the last 6 page signals received.  
 
Page signals will be shown one by one, beginning with the most recent. 
 
The receiver will beep once for an alarm page, but will not beep for a manual page.  
 
The receiver will beep three times to indicate that all signals have been viewed, or that no 
signals are stored. 
 
Two consecutive page signals carrying the same information are treated as one. 
 
Turning off the receiver will erase all stored signals.