Справочник Пользователя для Avaya 03-300430

Скачать
Страница из 2574
Communication Manager Maintenance-Object Repair Procedures
1540 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Table 564: Media Processor MAPD Circuit Pack Maintenance Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
)
0
Any
Any
Any
test board location
)
0
Circuit  pack 
removed or 
SAKI (#53)
MIN
WRN
1
1. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit 
pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a 
period of 15 minutes. Warning alarms are also raised against any ports administered on the circuit pack.
ON
)
0
busyout 
board 
location
WRN
OFF
release board location
0
WRN
OFF
add ip-interface board 
location
125 (
None
None
MIN
WRN
2
2. Minor alarms on this MO may be downgraded to warning based on values in set options.
ON
257 (
65535
Control 
Channel Loop 
test (#52)
MIN
ON
test board location l r 2
1538 (
Any
Hyperactivity
MIN
ON
1793
Any
NIC Loss Of 
Signal
MIN
test board location l r 2
2049 (
Any
NT PC Failure
MIN
reset board location
2305
Any
IP Address 
Inconsistency
test board location l r 2
2561
Any
Ping Error
MIN
test board location l r 5
3841 (
4358
Log Only
3999 (
Any
None