1579
MET Line Ringer Update Test (#62)
In this update, a “ringer on” or a “ringer off” message is sent to the firmware to start and stop the
ringer on the set.
ringer on the set.
Table 584: Test #62 MET Line Ringer Update Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
3
ABRT
This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
present, release the port using release station extension and
run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may
be busy with a valid call.
be busy with a valid call.
1. Use display port location to determine the station extension of
the port. Use status station to determine the service state of the
port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Station Ringer Update passed.
1. If complaints persist, investigate using other circuit pack tests, and by
examining the terminal, wiring, and connections.
1 of 2