SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2061
2306
ABRT
The SNI circuit pack is not responding to test requests sent by software.
1. Run test led switch-node for the switch node where the SNI
resides to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on
this board do not light, run test 760 using test board location l
for the active SNC in this carrier. Wait 5 minutes and then try step 1
one more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNI may be service interrupting. See
one more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNI may be service interrupting. See
on page 2046 for the procedure for replacing an
SNI.
3. If none of the LEDs light for the boards in the same carrier as this
board, fix any problems associated with the connectivity of this carrier
to the server.
to the server.
a. Check list fiber-link to see the fiber connections to this
carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
4. Follow the procedure described above, SNI Manual Loopback to
determine whether the circuit pack or the fiber connection is faulty.
Table 749: TEST #755 SNI Circuit Path Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation