Справочник Пользователя для Avaya 03-300430

Скачать
Страница из 2574
Communication Manager Maintenance-Object Repair Procedures
2226 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Signaling Link State (#1251)
This test is nondestructive.
This test checks the current state of the signaling link. The test looks at the board-level 
translations, checks that the board is physically inserted, gets the state of the D channel and 
service state of the port.
The test passes if the signaling link (D channel) is connected and operating normally. The test 
fails if the board is not installed, the signaling link is disconnected, or if the port is out of service. 
The test aborts otherwise.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1. Destructive; ND = Nondestructive
Signaling Link State Check test (#1251)
X
X
ND
Service State Audit test (#256)
X
X
ND
Call State Audit test (#257)
X
X
ND
ISDN Test Call test (#258)
S8300
 / 
G700
: Aborts with Error Code 1412 on a G700.
X
ND
Table 797: Test #1251 Signaling Link State Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1018
ABRT
The test is disabled.
1. Enable the test by entering enable test 1251.
 1 of 2