Справочник Пользователя для Bosch ICP-CC488

Скачать
Страница из 118
ICP-CC488 | Installation Guide | 20.0  
RF Information 
EN | 89 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
8 – Enable RF Jamming Monitor 
If this option is selected, the RF receiver monitors the 
background RF levels. If this level reaches a preset 
limit, the receiver assumes it is being jammed. This 
generates a fault on the codepad and sends an RF 
Jamming Report to the monitoring station. 
20.2  RF Device Mapping Option 
Location 
600 to 615 
 
Location Default 
Map RF Device 1  
600 
Map RF Device 2  
601 
Map RF Device 3  
602 
Map RF Device 4 
603 
Map RF Device 5  
604 
Map RF Device 6  
605 
Map RF Device 7 
606 
Map RF Device 8 
607 
Map RF Device 9 
608 
Map RF Device 10  
609 
Map RF Device 11 
610 
Map RF Device 12  
611 
Map RF Device 13  
612 
Map RF Device 14  
613 
Map RF Device 15  
614 
Map RF Device 16  
615 

1  
Mapping Disabled 
Mapping Enabled 
These locations allow you to enable or disable any of 
the sixteen RF devices.  For example, if location 607 
is set to “0”, RF device 7 is not mapped and is 
disabled. 
20.3  Default RF Device Mapping 
(Devices 1 to 8) 
Location 
616 to 623 
 
Location Default 
Value*
Map RF Device 1 to Zone 
(1 to 16) 
616 00 
Map RF Device 2 to Zone 
(1 to 16) 
617 01 
Map RF Device 3 to Zone 
(1 to 16) 
618 02 
Map RF Device 4 to Zone 
(1 to 16) 
619 03 
Map RF Device 5 to Zone 
(1 to 16) 
620 04 
Map RF Device 6 to Zone 
(1 to 16) 
621 05 
Map RF Device 7 to Zone 
(1 to 16) 
622 06 
Map RF Device 8 to Zone 
(1 to 16) 
623 07 
0-15  
Mapping RF device to zone 1-16 
The programming for zone numbers 1 through 8 is in 
hexadecimal code (00 through 15). 
These locations allow you to allocate RF wireless 
devices 1 to 8 to any of the 16 zones on the control 
panel. You cannot map more than one RF wireless 
device to the same zone. Refer to Section 20.4 Default 
RF Device Mapping (Devices 9 to 16)
 to map RF wireless 
devices 9 to 16. By default, RF devices 1 to 8 are 
mapped separately to each of the eight zones (that is, 
Device 1 is mapped to Zone 1, Device 2 to Zone 2, 
and so on). Locations 616 to 623 and locations 624 to 
631 can be programmed as any value from 00 to 15. 
Refer to Section 20.5 Using Hexadecimal Values for RF 
Device Mapping
 on page 89 for mapping information.  
 
20.4  Default RF Device Mapping 
(Devices 9 to 16) 
Location 
624 to 631
 
 
Location 
Default 
Map RF Device 9 to Zone 
(1 to 16) 
624 08 
Map RF Device 10 to 
Zone (1 to 16) 
625 09 
Map RF Device 11 to 
Zone (1 to 16) 
626 10 
Map RF Device 12 to 
Zone (1 to 16) 
627 11 
Map RF Device 13 to 
Zone (1 to 16) 
628 12 
Map RF Device 14 to 
Zone (1 to 16) 
629 13 
Map RF Device 15 to 
Zone (1 to 16) 
630 14 
Map RF Device 16 to 
Zone (1 to 16) 
631 15 
0-15  
Mapping RF device to zone 1-16 
The programming for zone numbers 9 through 16 is in 
hexadecimal code (00 through 15). 
These locations allow you to map RF wireless control 
panel. You cannot map more than one RF wireless 
device to the same zone. Refer to Section 20.3 to map 
RF wireless devices 1 to 8. 
By default, RF devices 9 through 16 are mapped 
separately to each of the eight zones (that is, Device 9 
is mapped to Zone 9, Device 10 to Zone 10). 
Locations 616 to 623 and locations 624 to 631 can be 
programmed as any value from 00 to 15. Refer to 
Section 20.5 Using Hexadecimal Values for RF Device 
Mapping
 on page 89 for mapping information. 
20.5  Using Hexadecimal Values for RF 
Device Mapping 
To map an RF device, first select a device number 
and enable the device. Refer to Section 20.2 RF Device 
Mapping Option
 on page 89.