Справочник Пользователя для Bosch LTC 8800

Скачать
Страница из 126
LTC 8600 | LTC 8800 Series
en | 35
F.01U.127.393 | 2.0 | 2009.03
Instruction Manual
Bosch Security Systems, Inc.
1. If using an Allegiant software package, attach the PC security key provided with 
the software to an available port on the computer.
The supplied interconnect cable utilizes a custom pinout. If it ever becomes 
necessary to replace the cable, it can be ordered separately using part number: 
LTC 8506/00. Alternatively, a cable can be configured using the information 
found in the Appendix Section of this manual.
2. Attach one end of the supplied RS-232 interface cable to the main Allegiant 
CPU bay connector marked 
Console (or another port that has been configured 
to operate as a Console port).
3. Attach the other end of the cable to an available serial port (COMM PORT 1 or 
COMM PORT 2) on the rear of the computer.
4. Apply power to the computer and allow it to boot up its operating system 
before inserting the software disc.
5. Refer to the applicable Allegiant software manual for complete programming 
instructions.
6. The communication settings of the PC must match those of the Allegiant. The 
Allegiant communication settings can be changed using Keyboard User Func-
tion 30 (described later in this manual), or may have been previously set using 
the Master Control Software. The factory default values are as follows:
Baud Rate
115200
Stop Bits
1
Data Bits
8
Parity
None