14.2 User Selectable DIP Switch Settings for LTC 8816/00 Data 
Receiver Modules used in LTC 8802 Series Monitor Expansion 
Bays
NOTE
After changing any of the following switches, the system must be powered off and 
on using the LTC 8802 Series monitor expansion main power switch.
14.2.1 Upper Data Receiver DIP Switch S1
LTC 8816/00 data receiver modules supplied in the LTC 8802 Series bays contain 
three (3) 8-position DIP switches. The settings of the upper DIP switch do not need 
to be changed from their factory default positions except when it is necessary to 
change the factory default format for the internal raster generator or if a problem 
occurs downloading new firmware into the data receiver module. The following 
table list these functions:
Switch 1 of S1
This switch selects the frequency of the internal raster generator used for dis-
play of on-screen text during video loss conditions. When set to 
OFF, the raster 
is generated at 60 Hz (default for 120 VAC models). When 
ON, the raster is gen-
erated at 50 Hz (default for 220-240 VAC models). To set the DIP switch 
changes. power the unit 
OFF and then turn the unit ON.
Switch 2, 3, and 4 of S1
These switches are not used in these systems and should be left 
OFF.
Switch 5 of S1
In the 
ON position, this switch forces the data receiver into a “boot” mode so it 
can accept a download of an operating system program via its console port. 
When this mode is enabled, the baud rate is fixed to 115200 and hardware 
handshake is 
ON.
Switch 6, 7, and 8 of S1
These switches do not currently provide user selectable options and should be 
left 
OFF.
DIP Switch Number Factory Default Setting “Upper” S1 DIP Switch Function
1
ON/OFF
Raster Generator Mode
2
OFF
Not  Used
3
OFF
Not  Used
4
OFF
Not  Used
5
OFF
Boot  Mode
6
OFF
Not  Used
7
OFF
Not  Used
8
OFF
Not  Used