Справочник Пользователя для Desa VF-24N-BTB

Скачать
Страница из 32
111826-01F
For more information, visit www.desatech.com
15
15
OPERATING HEATER (REMOTE-READY MODELS)
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Remote Control Operation
OPERATING HEATER
Continued 
Figure 18 - Control Knob and Ignitor Button Location,   
                           Remote Ready Controlled
Remote Control
7.  With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front 
burner. If needed, keep press ing ig ni tor button until pilot 
lights.
 
Note: If pilot does not stay lit, con tact a qualifi ed service 
person or gas sup pli er for repairs. Until repairs are made, 
light pilot with match. To light pilot with match, see Man u al 
Light ing  Procedure
, column 2. 
8.  Keep control knob pressed in for 30 seconds after lighting 
pilot. After 30 seconds, release control knob.
•  If control knob does not pop out when released, contact 
a qualifi ed ser vice person or gas supplier for re pairs.
 
Note: If pilot goes out, repeat steps 4 through 8, pages 
14 & 15.
9.  Slightly push in and turn control knob counterclockwise 
  to the ON position.
10.  Wait one minute and switch selector switch to the ON po-
 si tion  to  light  burners. 
Note: AUTO is only func tion al when 
using GWMT1 or GWMS2 optional accessories.
11. Set fl ame adjustment knob to any lev el be tween HI and 
LO.
  CAUTION: Do not try to ad just heating levels by 
using the equipment shutoff valve.
  WARNING: Make sure the selector switch is in the 
OFF po si tion when you are away from home for long 
periods of time. Heater will come on au to mat i cal ly 
with selector switch in the ON position.
Shutting Off Heater
1.  Turn control knob clockwise  
   to the OFF po-
 si tion.
2a.  Set selector switch in the OFF po si tion.
2b. 
If Using Optional Hand-Held Re mote: Set selector switch 
in the OFF po si tion to pre vent drain ing battery. 
Shutting Off Burner Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing 
one of the fol low ing: 
1.  Turn control knob clockwise  
   to the PILOT po-
 si tion.
2.  Use remote control manual OFF button.
3.  Set selector switch in the OFF po si tion.
Figure 19 - Pilot (Propane/LP)
Ignitor 
Electrode
Pilot 
Burner
         Pilot (Natural)
Ignitor 
Electrode
Pilot 
Burner
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
1.  Fol low steps 1 through 6 under Light ing  In struc tions, page 
14.
2.  Depress control knob and light pilot with match. 
3.  Keep control knob pressed in for 30 seconds after lighting 
pilot. After 30 seconds, release control knob. Now follow 
steps 9 through 11, Lighting In struc tions
, column 1.
O
F
F
PI
LOT
O
N
LO
IH
AUTO
OFF
ON
Control Knob
Ignitor Button
Flame Adjustment Knob
Selector Switch in
OFF Position
REMO
TE OFF ON
Remote Control Operation
GHRCB Series Operation:
1.  After lighting, let pilot fl ame burn for about one minute. 
Turn control knob to ON position. Adjust fl ame ad just ment 
knob anywhere between HI and LO. Slide the se lec tor 
switch to the RE MOTE po si tion. 
Note: The burn ers may 
light if hand-held re mote ON button was on when se lec tor 
switch was last turned off. You can now turn the burn ers 
on and off with the hand-held re mote con trol unit. 
REMOTE CONTROL OPERATION