Справочник Пользователя для Majestic Appliances UVS36RN

Скачать
Страница из 24
16
UVS33/36 Vent-Free Heaters
20002211
Maintenance
Burner and Burner Compartment
It is important to keep the burner and the burner 
compartment clean. At least once per year the logs and 
lava rock/ember material should be removed and the 
burner compartment vacuumed and wiped out. Remove 
and replace the logs as per the instructions in this 
manual.
Always handle the logs with care as they are fragile 
and may also be hot if the fireplace has been in  
use.
FK12/FK24 Fan Assembly
The fan unit requires periodic cleaning. At least once 
per month in the operating season, open the lower 
louvre panels and wipe or vacuum the area around the 
fan to remove any build up of dust or lint.
Cleaning the Standing Pilot 
Control System
The burner and control system consists of:
• main burner  
• pilot burner 
• gas orifice   
• thermopile
• combination millivolt gas valve
Most of these components may require only an occa-
sional checkup and cleaning and some may require ad-
justment. If repair is necessary, it should be performed 
by a qualified technician.
In order to properly clean the burner and pilot assembly, 
turn off the gas to the unit, remove the window frame 
panel and logs exposing the burner and pilot assembly. 
Clean all foreign materials from the top of the burner. 
Check to make sure that burner parts are clean. Visu-
ally inspect pilot. Brush or blow away any dust or lint 
accumulation If pilot orifice is plugged, disassembly 
may be required to remove any foreign material from 
the orifice or tubing.
Fig. 21  Proper pilot flame height.
FP449
IF449 
NOVA SIT PILOT
UVC
2/14/97
To obtain proper operation, it is imperative that the pilot 
and burner's flame characteristics are steady, not lifting 
or floating.
Typically, the top 1/8" of the thermopile should be en-
gulfed in the pilot flame. (Fig. 21)