SECTION 4: N
ATIONAL
 S
TANDARDS
 
AND
 A
PPLICABLE
 C
ODES
9
4.6 High Altitude
These heaters are CSA-approved (without 
modifications) for installations up to 2000' (610 
m) in US and Canada. CSA approved heaters 
installed above 2000' (610 m) must be de-
rated. For installations above 2000' (610 m) in 
US, consult factory for information on burner 
de-rating. For installations from 2000' (610 m) 
to 4500' (1370m) in Canada, high altitude 
conversion kits are available. Heaters installed 
over 4500' (1370 m) in Canada are not CSA-
approved and must be approved by the local or 
provincial authority.