Справочник Пользователя для Roberts Gorden UHA[X][S] 125

Скачать
Страница из 62
SECTION 9: W
IRING
23
SECTION 9: WIRING
All heater models require constant 120 V/1Ø/ 60 Hz  
power supply. Check heater rating plate for electrical 
rating for proper circuit sizing. For servicing, a 
disconnect switch of proper electrical rating should 
be installed in the vicinity of the heater.
All heaters are equipped with thermostat 
connections suitable to power a 24 V thermostat.
Heater must be wired and electrically grounded in 
accordance with local codes. In the absence of local
codes in accordance with: United States: refer to 
National Electrical Code
®
 NFPA 70 - latest revision; 
Canada: refer to Canadian Electrical Code CSA 
C22.1 Part I - latest revision. 
9.1 Positioning Thermostats 
A room thermostat should be mounted on a 
vibration-free wall or column at a height of 
approximately 5' (1.5 m) from the floor to measure 
the ambient temperature. It should be clear of both 
cold drafts and the direct path of warm air from the 
heater.
Avoid mounting thermostat on outside walls or in 
areas directly exposed to radiant heat or sunlight.
 
Install wall tag in a visible location near thermostat 
See Page 5, Section 2.1 for wall tag details.
9.1.1 Fan Control
The heater’s axial fan can be used during the off-
season for air circulation. A low-voltage 
programmable thermostat with a fan switch (P/N 
90425400) must be See Page 23, Section 9.2
used. For thermostat connection details. For the use 
of multiple heaters on one thermostat, See Page 24, 
Section 9.3
  through Page 25, Section 9.4
9.2 Low Voltage Thermostat with One Heater
WARNING
Electrical Shock Hazard
Disconnect electrical and gas supply before 
servicing.
This appliance must be connected to a 
properly grounded electrical source.
Failure to follow these instructions can 
result in death or electrical shock.
Electrical 
Supply
Terminal
Strip
R
G
W
C
R
W
Electrical 
Supply
R
G
W
C
R
G
Terminal
Strip
24 Volt
Thermostat
Heating 
Only
24 Volt
Thermostat
with Fan 
Control
W
C
Gas 
Supply
Gas 
Supply