Vermont Castings Intrepid Multi-Fuel
2000970
 
Side 
Rear 
Corners 
Side  
Rear 
Corners 
  (A) 24” 
(B) 30” 
(C) 20” 
(D) 12” 
(E) 16” 
(F) 10”
  (610 mm)  (762 mm) 
(508 mm) 
(305 mm)  (410 mm) 
(254 mm)
  (G) 24” 
(H) 16” 
(I) 12” 
(J) 12” 
(K) 9” 
(L) 10”
  (610 mm)  (410 mm) 
(305 mm) 
(305 mm)  (229 mm) 
(254 mm)
 
  (M) 24” 
(N) 14” 
(NA) 
(P) 12” 
(Q) 9” 
(NA)
  (610 mm)  (356 mm) 
 
(305 mm)  (229 mm) 
  (G) 24” 
(H) 16” 
(I) 12” 
 
*
  (610 mm)  (410 mm) 
(305 mm)
Intrepid Multi-Fuel Clearance Chart
See Pages 14 and 16 for illustrations of these clearances.
All Installations
Unprotected Surfaces
Top exit, rear stove h.s., 
single-wall chimney 
connector with connector 
heat shields 
1,2
No stove heat shields
Rear exit, rear stove 
heat shield only 
3
Top exit, rear stove  
h.s., double-wall  
chimney connector
5
Single-wall chimney 
connector, no  
connector heat shields
Single-wall chimney 
connector,  with 
connector heat shields 
Double-wall 
connector
5
* Clearances with double-wall connectors and protected surfaces have not been tested for the Intrepid.
1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1” (25 mm) below the 
ceiling heat shield, which is 22” (559 mm) in diameter.  The ceiling heat shield should be 24 gauge or heavier sheet metal, centered 
on the chimney connector, and mounted on non-combustible spacers.
3. Rear exit—horizontal from flue collar directly back through wall.
4. The ceiling heat shield required when chimney connector shields are used should meet the wall protector.  This will require trim-
ming the ceiling shield along the line of intersection with the wall protector.
5. In top exit installations, this clearance requires the use of the rear heat shield with the shield insert installed.
Protected Surfaces
Chimney Connector Clearance
Stove Clearance
48”  (1219 mm)
Front Clearance to Combustibles
12”  (305 mm)
5”  (127 mm)
4
10”  (254 mm)
26 “  (661 mm)
*
12”  (305 mm)
 
Stove Installed 
Stove in 
Stove Installed 
Stove in
 
Parallel to Wall 
Corner 
Parallel to Wall 
Corner