Справочник Пользователя для Aprilaire 600 &700

Скачать
Страница из 19
- 7 -
reverse  the  dial  direction  slowly  until  you  hear  the  solenoid  valve
“click  on”.  At  this  point,  read  the  RH  on  the  dial.  This  will  be  very
close to the actual RH in your home. (See Figure B)
To check the humidifier operation, set the knob to “test”, make
sure that the water saddle valve is open and that there is electricity
to the unit. Generally, the furnace blower motor must be operating
for the Aprilaire Humidifier to function. After the humidifier has oper-
ated for one minute and water is entering the unit and coming out at
the drain, reduce the humidistat setting to the recommended inside
relative  humidity,  depending  on  the  outside  temperature.  DO NOT
LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. Follow the
suggested settings prior to a drop in the outside temperature.
MANUAL MODE
(Figure B)
tion  of  too  high  relative  humidi-
ties. This same condensation can
take  place  in  other  areas  in  your
home with the possibility of dam-
age resulting.
The  humidistat  is  a  precision
instrument  that  can  be  used 
to determine the RH accurately in
your home during the winter. Turn
the  dial  to  the  lower  setting,  then
Outside Temperature 
Recommended RH
+40°
45%
+30°
40%
+20°
35%
+10°
30%
25%
–10°
20%
–20°
15%
(Table 3) Outdoor-Indoor Relative Humidity