Programming
F232182
14
Degrees Displayed in Fahrenheit or 
Celsius
This setup option affects the programming and display 
of all temperatures. If “FAr” is selected, all 
temperatures will display in Fahrenheit. If “CEL” is 
selected, all temperatures will display in Celsius. 
Acceptable ranges for programmable temperatures are 
75° – 200°F or 25° – 93°C.
Procedure for Temperature Calibration
1. Ensure that the V-Computer has no input power 
applied.
2. Mount an accurate temperature sensor probe 
(part of temperature calibration equipment) in the 
bottom of the machine basket. Make sure the 
wires for the probe exit the top of the door to 
ensure the door gasket does not leak.
3. Close door and ensure that the door is locked.
4. Open machine top cover and remove control 
component cover(s), if necessary, to gain access 
to the V-Computer and output control board.
NOTE: For more accurate calibration proceed with 
steps 5-9. For a quick estimated calibration skip to 
step 10.
5. Note wire connections on the output control 
board for the AC Drive control. Some machines 
will have six wires connected to “STF,” “STR,” 
“RH,” “RM,” “RL,” and “COM” individually or a 
single connector labeled “J11-1.” Remove these 
wires or connector to ensure the basket will not 
rotate. Also remove the input power to the drive.
NOTE: If this step is not followed, damage can 
occur to the calibration temperature probe.
6. Restore input power to the machine. 
7. Wait until machine message displays “CY” 
followed by a two-digit cycle number (01 – 30).
8. Program one of the unused cycles to Fill to High 
Level using both of the water inlet valves. Select 
a time limit that would be sufficient to complete 
the calibration procedure.
9. When machine has completed the Fill to High 
Level, press and hold the Up key to display the 
machine temperature. Make sure that the 
V-Computer is in the correct temperature unit 
(deg F or C). Refer to Setup Mode section of 
manual to change.
10. Using a flat bladed screwdriver, turn the machine 
temperature calibration screw until the displayed 
temperature of the machine and the temperature 
of the temperature calibration equipment are 
accurate to the nearest degree (refer to Figure 4).
11. When the temperatures match, calibration is 
completed. 
12. Remove power from the machine input.
13. Reconnect any wires/connectors/fuses that were 
removed, making sure they are installed exactly 
as they were removed.
14. Reinstall all machine protective covers.
15. Remove the temperature calibration probe from 
the bottom of the machine basket.
16. Restore input power to machine.
17. Machine is now ready for use. 
Dangerous voltages are present in the 
electrical control box(es) and at the motor 
terminals. Only qualified personnel 
familiar with electrical test procedures, 
test equipment, and safety precautions 
should attempt adjustments and 
troubleshooting. Disconnect power from 
the machine before removing the control 
box cover, and before attempting any 
service procedures.