Справочник Пользователя для Shark KD450W

Скачать
Страница из 20
13
www.sharksonicduo.com
Troubleshooting Guide
PROBLEM
POSSIBLE REASONS & SOLUTIONS
Sonic Duo
 is squirting 
foam from the spray nozzle.
1.   The Reusable Bottle is not firmly inserted into the unit. Make sure that you hear an audible 
“Click” when you insert the Reusable Bottle into the appliance. 
2.   There may be air in the system. Hold down the spray button for 5 to 10 seconds to flush the 
system.
Sonic Duo
 doesn’t spray.
1.   Make sure that the Reusable Bottle is inserted all the way in. You should hear an audible 
“Click” when inserted.
2.   Check that there is enough cleaning solution in the Reusable Bottle. If not, add more.
3.   The bottle cap on the Reusable Bottle may need to be cleaned. Remove it from the Reusable 
Bottle and rinse it under running water and then replace it onto the Reusable Bottle.
4.   There may be air in the system. Hold down the spray button for 5 to 10 seconds until solution 
comes out of the spray nozzle.
5.   The colored spray nozzle at the front of the unit where the spray comes out may be clogged. 
Clean the spray nozzle by removing it from the unit. To remove it, grip the small lips at the 
top and bottom of the spray nozzle and turn counterclockwise. Run the spray nozzle under 
warm water to clean it out. Reinsert the spray nozzle by lining up its grooves with the inside 
of the nozzle hole. Turn clockwise until the lips return to the top and bottom positions. 
Sonic Duo
 turns off when 
the handle is lowered.
1.   The  Sonic Duo™ automatically turns off when the handle is lowered to low. This is a 
safety mechanism to ensure that the machine will turn off if it is dropped. To keep the Sonic 
Duo™ on when cleaning under low profile items, simply twist the handle to the left or right 
and engage the swivel. When the handle is swivelled and lowered, the Sonic Duo™ will 
remain on.
The cap of the Reusable Bottle 
is stuck inside the Sonic 
Duo
 
after the bottle was 
removed.
1.   To remove the cap, hold center valve of the cap with your fingers and gently pull it out. If it 
doesn’t come out easily, use a set of long nose pliers for leverage. Be careful not to crack the 
center valve when applying pressure and lifting up.
The Reusable Bottle fell out.
1.   The  Sonic Duo™ is not meant to be turned upside down. When upside-down, the Reusable 
Bottle is at risk for falling out of its cradle. Please do not turn the Sonic Duo™ upside-
down. If it is necessary to turn the unit upside-down, remove the Reusable Bottle first.
Sonic Duo
 turns off on 
its own.
This unit is equipped with an automatic protector. If for some reason your appliance 
overheats, the protector will automatically turn the unit off. Should this occur, perform 
the following steps to restart the appliance:
1. Move the switch to the “O” (Off) position.
2. Unplug.
3. Allow the unit to cool for around 45 minutes.
4. Plug in.
5. Turn the switch on to restart.
 
Note: If appliance still does not start, contact Customer Service at:
1-800-798-7398.
KD450W_26_IB_E_130511_1.indd   13
13-03-11   3:43 PM