Справочник Пользователя для Aprilaire 1770A
SPECIfICATIONS
Dimensions: 20-3/4”W x 24”L x 20-5/8”H
Adjustable feet allow for 22-5/8” total height
Weight: 1750A – 93 lbs .
1770A – 100 lbs .
Capacity: 1750A – 90 pints per day @ 275 CFM
1770A – 135 pints per day @ 500 CFM
AHAM DH-1-2003 80°F, 60%RH conditions
AHAM DH-1-2003 80°F, 60%RH conditions
Power: 1750A – 115 VAC, 8 A, 15 A circuit
1770A – 115 VAC, 14 A, 20 A circuit
Unit equipped with 8 ft . grounded power cord
Unit equipped with 8 ft . grounded power cord
Operating Conditions:
Compressor: 50°F–100°F, 40°F dew point minimum
Ambient/Inlet Air: 40°F–140°F, 0%–95% RH (non-condensing)
Ambient/Inlet Air: 40°F–140°F, 0%–95% RH (non-condensing)
filter: MERV 8, washable
Compressor Minimum Off Time: 3 minutes
Compressor Minimum On Time: 3 minutes
Compressor Minimum Off Time: 3 minutes
Compressor Minimum On Time: 3 minutes
Airflow:
1750A
External Static Pressure
Airflow
0 .0 “w .c .
385 CFM
0 .4 “w .c .
340 CFM
0 .6 “w .c .
275 CFM
1770A
External Static Pressure
Airflow
0 .0 “w .c .
535 CFM
0 .7 “w .c .
515 CFM
0 .9 “w .c .
500 CFM
UNPACKING AND CONTENTS
Do not tip unit to remove from carton.
1 . Open carton completely by cutting each corner
1 . Open carton completely by cutting each corner
from top to bottom .
2 . Remove all cardboard inner pack .
3 . See
3 . See
figure 1 for opening view and contents .
a . Installation Instructions
b . Owner’s Manual
c . Duct Collars, 2
d . Drain Trap
e . 90° PVC Elbow
f . Backflow Damper
b . Owner’s Manual
c . Duct Collars, 2
d . Drain Trap
e . 90° PVC Elbow
f . Backflow Damper
fIGURE 1 – Opening View and Contents
b
a
c
d
e
f
90-1539
3