CHEMICAL AND STAIN RESISTANCE 
 
 
This test was conducted in accordance with ASTM F 925, Resistance to Chemicals of Resilient Sheet Flooring.  
By this test, a specified reagent is applied to the surface of the flooring material and allowed to remain in contact 
for 60 =/- 1 minute.  After the exposure of time, the reagent is cleaned from the surface using warm water and 
the surface dried.  Within 5 minutes after removal of the reagent, the material is visually examined and the 
exposed area compared to the adjacent unexposed area.   
 
The following categories are rated:   
 
Surface Dulling—indicating that the specimen suffered a loss of gloss 
 
Surface Attack—indicating that the specimen suffered surface damage such as softening, warping, 
swelling, blistering, peeling, raised, or rough area 
 
Color Change—indicating that the specimen suffered discoloring or bleaching or both.   
 
Each category is rated as No Change=NC, Slight Change=SC, Moderate Change=MC, or Sever 
Change=SC.  After 24 hours, the exposed specimens are re-examined and similarly rated. 
 
 
Chemical 
Five Minutes 
24 Hours 
 
 
Surface
Dulling
 
Surface 
Attack 
 
Color 
Change 
 
Surface 
Dulling 
 
Surface 
Attack 
 
Color 
Change 
 
5% Acetic Acid 
 
 
NC 
 
NC 
 
NC 
 
NC 
 
NC 
 
NC 
 
 
 
 
 
 
 
70% Isopropyl Alcohol 
NC 
NC 
NC 
NC 
NC 
NC 
 
 
 
 
 
 
 
Mineral Oil 
 
NC NC  NC  NC  NC  NC 
 
 
 
 
 
 
 
5% 
Sodium 
Hydroxide 
NC 
NC NC  NC NC NC 
 
 
 
 
 
 
 
5% 
Hydrochloric 
Acid 
NC 
NC NC  NC NC NC 
 
 
 
 
 
 
 
5% Ammonium 
Hydroxide 
NC 
NC NC  NC NC NC 
 
 
 
 
 
 
 
5.25% Sodium Hypo 
chlorite 
NC 
NC NC  NC NC NC 
 
 
 
 
 
 
 
5% Phenol 
 
NC 
NC NC  NC NC NC 
 
 
 
 
 
 
 
 
 
Unleaded Gasoline 
 
NC NC  NC  NC  NC  NC