Справочник Пользователя для Honeywell 69-2035EFS-05

Скачать
Страница из 36
Operating Manual
69-2035EFS—05 
With automatic controls like TrueIAQ and VisionPRO 
IAQ, you need only calibrate this setting once. The 
automatic feature will adjust by itself as outdoor condi-
tions change, based on your initial settings. After set-
ting your auto control to the desired RH% level, check 
for condensation or frost forming on windows on the 
first cold day. If present, adjust your frost settings on 
the control (see control owner’s manual if needed).
The Window Frost Protection feature protects your 
home by limiting humidity output based on outdoor 
conditions (for example, on colder days, your home can hold less humidity).
Frost Settings should be lowered by one value each morning that you see frost or condensa-
tion on windows. Allow 24 hours for the adjustment to take affect. Once you have this set to a 
comfortable level without condensation forming, you will not need to adjust this again. You can 
adjust your humidity settings without worrying about condensation. 
With Manual Humidity Controls—such as the H8908—you 
will need to adjust your RH% settings each time the outdoor 
conditions change (more humidity with warmer outdoor con-
ditions, lower humidity with colder conditions). These con-
trols provide accurate operation, but require more hands on 
adjustment. These controls are a good choice for homeown-
ers who desire continuous interaction with humidity settings.
Setting the controls
The colder it is outside, the less humidity can be retained by the air. Initially setting your humidi-
stat to ideal comfort levels will help your TrueSTEAM deliver optimal humidification. The table 
below provides suggested control settings based on outdoor conditions.
M24830
1
2
3
4
5
6
7
8
9
LESS HUMIDITY
LOOSE HOME/SINGLE-PANE WINDOWS
MORE HUMIDITY
TIGHT HOME/TRIPLE-PANE WINDOWS
You may experience that your home needs 
humidity levels to be slightly higher or lower 
than the suggested levels given in the table, in 
order to prevent window condensation or dry-
ness. This is because your home is unique in 
size, shape, building tightness, and age. These 
variables play an active role in how your indoor 
humidity fluctuates. Use the table as a start-
ing point, but adjust according to your comfort 
and observations of condensation.
Outdoor 
Temperature
Recommended RH % 
Setting
-20°F (-29°C)
15%
-10°F (-23°C)
20%
0°F (-18°C)
25%
10°F (-12°C)
30%
20°F (-7°C)
35%
>20°F (-1°C)
40%