STEP 2:
  Adjusting the Sensitivity Force — Sensitivity System force adjustment screws are located on the side rails of the Power 
Unit and can easily be adjusted with a screwdriver.  Turn the screws CLOCKWISE for more force and COUNTERCLOCKWISE 
for less force.     
STEP 3: 
Testing the Sensitivity Force — To test the Sensitivity System, start the Opener and grasp the bottom door handle halfway 
through the door's travel (opening or closing).  When testing in the CLOSE direction, a second person will be needed to maintain 
pressure on the Push Button IF an Auxiliary Entrapment Protection Device has not yet been fitted.  If a second person is unavailable, 
use a stiff cardboard carton placed in the door's downward path to indicate the force the Opener is exerting. If the force adjustment 
screws are properly set, the door should stop if opening, and reverse if closing without exerting undue pressure.  
      
W A R N I N G
 
IMPROPER ADJUSTMENT OF SENSITIVITY SYSTEM 
FORCE COULD CAUSE ENTRAPMENT, INJURY OR 
DEATH.  SET ADJUSTMENTS FOR JUST ENOUGH 
FORCE TO OPERATE THE DOOR RELIABLY, BUT NO 
STRONGER.  Contact a service professional to correct 
any binding, sticking or other door problems.  DO NOT 
OVER-ADJUST SENSITIVITY SYSTEM TO 
COMPENSATE FOR A POORLY WORKING DOOR. 
             
W A R N I N G
 
THE SENSITIVITY SYSTEM REVERSING TEST SHOULD BE 
PERFORMED MONTHLY TO ENSURE THAT THIS IMPORTANT 
SYSTEM REMAINS IN PROPER ADJUSTMENT. 
  W A R N I N G
 
FAILURE TO TEST 
REVERSING SYSTEM 
COULD RESULT IN 
DEATH OR SERIOUS 
INJURY.  TEST THIS 
SYSTEM ONCE A MONTH 
BY FOLLOWING 
PROCEDURES OUTLINED 
STEP 4:
      Testing the Opener’s 
Reversing System — To test the 
Opener's Reversing Feature at floor level, 
place a solid object 1-1/2" thick (such as a 
standard 2 X 4 board laid flat) on the 
ground where the center of the door will 
contact it.  Close the door. If the down 
force adjustments are correct, the door 
will reverse within two seconds of 
contacting the object and travel to the Full 
Open position.  If this does not occur, 
recheck the Limit Adjustments (Page 17) 
and Sensitivity Adjustments (Step 2 & 3, 
Above). 
 
NOTE:
  Any time adjustments are 
made to Limits or Sensitivity, YOU 
MUST RETEST THE OPENER FOR 
THE REVERSING FEATURE AT 
FLOOR LEVEL AS OUTLINED 
ABOVE.
 
OPEN FORCE  
ADJUSTMENT 
CLOSE FORCE 
ADJUSTMENT 
104391 
1 1/2” BLOCK OF 
WOOD LAID FLAT 
(2”X4”) 
104392 
F:
 OPERATION AND ADJUSTMENT INSTRUCTIONS