INSTALLING THE OPERATOR 
STEP 6:  
Tie a 
double overhand 
knot
 in one end 
of the Manual 
Release Rope and 
slip the other end 
through the red 
Release Handle, 
the Release 
Instruction Card, 
and the hole at 
the end of the 
Release Lever on 
the Trolley. Tie a 
second double 
overhand knot 
in the free end
,  
adjusting the Rope so that the Red Handle is 6 FT 
above the floor
.  If the Rope must be cut, flame seal 
the cut end with a match or lighter. 
Step 9:  
Consult the label on the rear panel of the 
Opener to determine its proper working voltage.  
Normally it will be marked for 115V, 60 cycle 
operation.  (If it is an export model designed for 230V, 
50 cycle operation, the label will clearly indicate this.) 
The opener must be plugged into a properly grounded 
receptacle within 3 FT of the Power Unit.   Do not use 
2-prong adapters and do not use extension cords for 
anything more than temporary hook-up and testing 
purposes.  Receptacle wiring should be No. 14 or 
heavier, and must be in compliance with local 
building and electrical codes.
  
If local codes require permanent wiring, a resettable, 15 
Amp circuit breaker is recommended to protect the line.  
Remove the Strain Relief Bushing and withdraw the 
Line Cord from the rear of the Power Unit to expose 
the three insulated connectors.  Cut the wire at the 
rubber jacket of the Line Cord and wire in permanently, 
employing proper wiring practices.  Discard Strain 
Relief.  It is not used with permanent wiring 
 
Step 10:  
Install a Rough Service lamp bulb (75 Watt 
maximum) firmly in the light socket.  Light bulbs in 
door openers are subject to vibration during normal 
operation which may shorten their life spans.  Rough 
Service bulbs, available at most hardware stores, are 
recommended.  Fit Light Diffuser tabs into the panel 
slots as shown.  
RELEASE 
INSTRUCTION 
CARD 
DOUBLE 
OVERHAND 
KNOT 
FLOOR 
104378 
about location of, and attachment to, ceiling joists, a 
carpenter should be contacted to provide assistance.  A 
cross brace will be necessary if the power head is 
mounted 8” or more from the ceiling, see illustration 
at bottom of previous page.  Attach a kick brace from 
the hanger angle to an opposite end Power Unit 
mounting hole to provide horizontal stability as 
shown.  Optionally a hanger angle at the opposite end 
mounting hole can be used to provide horizontal 
stability. 
 
STEP 5:  
Return to the  
“T” Rail/Front 
Mounting 
Bracket 
and 
securely tighten 
the bolt and nut 
that connect the 
Tee Rail Front 
Idler bracket and the Front Mounting Bracket.  (See 
Step 2, previous).
 
104374 
 
Kick Brace 
Angle 
Hanger 
Angle 
DOUBLE 
OVERHAND 
KNOT 
 
 
DISCONNECT POWER 
AT FUSE BOX AND 
OPENER BEFORE 
WIRING PERMANENTLY 
TO PREVENT 
ELECTROCUTION. 
 WARNING 
IMPROPER WIRING COULD CAUSE 
ELECTROCUTION OR DAMAGE TO 
CIRCUITRY.  FOLLOW LOCAL BUILDING AND 
ELECTRICAL CODES. 
 
 
WARNING 
104380