Справочник Пользователя для Heat & Glo LifeStyle RED40

Скачать
Страница из 82
Heat & Glo  •  RED40, RED40ST •  2155-900 Rev. o
 
 •  7/12
7
C. BTU Specifi cations
MODEL: RED40, RED40ST
LABORATORY:  Underwriters Laboratories, Inc. (UL)
TYPE:  Vented Gas Fireplace Heater
STANDARD: ANSI Z21.88b-2008 CSA 2.33a-2008
 
Vented Gas Fireplace Heaters
This product is listed to ANSI standards for “Vented Gas 
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and 
Recreational Vehicles”, and “Gas Fired Appliances for 
Use at High Altitudes”.
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input 
BTU/h
Orifi ce
Size 
(DMS)
RED40
RED40ST 
(NG)
US
(0-2000 FT)
34,000
24,000
#34
CANADA
(2000-4500 FT)
29,500 22,000
#36 
RED40
RED40ST 
(LP)
US
(0-2000 FT)
34,000
25,000
#50
CANADA
(2000-4500 FT)
31,500
23,000
#51
E.  Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are 
those consisting entirely of steel, iron, brick, tile, concrete, 
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, 
Standard Test Method for Behavior of Materials in a 
Vertical Tube Furnace at 750 ºC 
and UL763 shall be 
considered non-combustible materials.
F.  Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa-
per, plant fi bers, plastics, or other material that can ignite 
and burn, whether fl ame proofed or not, or plastered or 
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE:  This appliance must be electrically wired and 
grounded in accordance with local codes or, in the absence 
of local codes, with 
National Electric Code ANSI/NFPA 
70-latest edition 
or the Canadian Electric Code CSA 
C22.1.
•  A 110-120 VAC circuit for this product must be protected 
with ground-fault circuit-interrupter protection, in compliance 
with the applicable electrical codes, when it is installed in 
locations such as in bathrooms or near sinks.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, 
these rules do not apply. Check with your local gas utility 
or authorities having jurisdiction.
When installing above 2000 feet elevation:
•  In the USA: Reduce input rate 4% for each 1000 feet 
above 2000 feet.
•  In CANADA: Reduce input rate 10% for elevations 
between 2000 feet and 4500 feet. Above 4500 feet, 
consult local gas utility.
Check with your local gas utility to determine proper 
orifi ce size.
NOTICE: This installation must conform with local codes. 
In the absence of local codes you must comply with the 
National Fuel Gas Code, ANSI Z223.1-latest edition in 
the U.S.A. and the CAN/CGA B149 Installation Codes in 
Canada.
Listing and Code Approvals 
 
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact 
your dealer for replacement glass.
A. Appliance Certifi cation