Справочник Пользователя для Vermont Casting DBR36

Скачать
Страница из 32
- 23 -
GAS SUPPLY ON
• SUPPLY LINE HOOKED UP
• SHUTOFF VALVE OPEN
NO
NO
NO
NO
• LOCKOUT HAS ENGAGED. WAIT 
  60 SECONDS AND TRY AGAIN.
• PIEZO NOT TIGHT ENOUGH 
  FOR GOOD GROUND.
• FOR SPARK AT ELECTRODE 
  WHILE DEPRESSING PIEZO 
  (RED BUTTON) — 1/8" GAP TO 
  PILOT HOOD NEEDED.
• ALL WIRING CONNECTIONS
• REPLACE PIEZO IGNITOR
• THERMODISK
• FOR AIR IN THE LINES
• THERMOPILE NEEDS A 
  MINIMUM 325mV. ADJUST 
  PILOT FLAME HEIGHT.
• ALL WIRING CONNECTIONS.
• REPLACE THERMOPILE
• THERMOCOUPLE NEEDS A 
  MINIMUM OF 14mV.
• DEFECTIVE VALVE. TURN TO 
  PILOT, METER SHOULD READ 
  GREATER THAN 100 mV. IF 
  NOT, REPLACE.
• THERMODISK 
PILOT LIGHTS WITH 
PIEZO IGNITOR
YES
YES
YES
YES
PILOT STAYS LIT
PILOT LIGHTS MAIN 
BURNER
SYSTEM OK.
START
CHECK
• WALL SWITCH IS NOT
  TURNED ON. WATCH 
  FOR GROUNDED WIRES!
•THERMOPILE NEEDS A 
  MINIMUM 325mV.
• PLUGGED BURNER ORIFICE.
TROUBLE SHOOTING  THE GAS CONTROL SYSTEM
HONEYWELL MILLIVOLT VALVE