Справочник Пользователя для Vermont Casting DBR36

Скачать
Страница из 32
- 6 -
Do not use this fireplace if any part of it has
been under water.  Immediately call a qualified
service technician to inspect the fireplace
and replace any part of the control which has
been under water.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Non-combustible materials such as brick and tile can be
extended over the outer face of the unit 
(Do not cover
louvres or glass door)
.  If a Trim Kit is going to be installed,
brick and tile will have to be installed flush with the side of
this appliance.
FINAL FINISHING
HEARTH
A hearth is not mandatory but it is recommended for
aesthetic purposes.  We recommend a non-combustible
hearth which does not obstruct louvre opening.
GAS SPECIFICATIONS
MAX.
MIN.
 INPUT
 INPUT
MODEL
FUEL
GAS CONTROL B.T.U.H
B.T.U.H.
DBR33 RN
Natural Gas
Millivolt Hi/Lo
15,000
10,500
DBR33 RP
Propane Gas
Millivolt Hi/Lo
15,000
11,250
DBR36 RN
Natural Gas
Millivolt  Hi/Lo
18,000
12,600
DBR36 RP
Propane Gas
Millivolt  Hi/Lo
18,000
13,500
DBR39 RN
Natural Gas
Millivolt Hi/Lo
22,000
15,400
DBR39 RP
Propane Gas
Millivolt Hi/Lo
22,000
16,500
CERTIFIED TO:
ANSI Z1.88b-1999/CSA Z2.33-M-99 harmonized,
standard for Vented Gas Fireplace.
Table 6
The installation of your Fireplace must
conform with local codes, or in the absence
of local codes, with National Fuel Gas Code,
ANSI Z223.1 — latest edition, or CAN 1 B1-
149.1 and .2 Installation Code.  (EXCEPTION:
Do not derate this appliance for altitude.
Maintain the manifold pressure at 3.5 inches
W.C. for Natural Gas and 10 inches W.C. for
LP gas.)
GAS INLET & MANIFOLD PRESSURES
Input Minimum
Input Maximum
Manifold Pressure
NATURAL
LP (Propane)
11" wc
13" wc
10" wc
4.5" wc
7" wc
3.5" wc
Table 7