Справочник Пользователя для Vermont Casting DBR36
- 6 -
Do not use this fireplace if any part of it has
been under water. Immediately call a qualified
service technician to inspect the fireplace
and replace any part of the control which has
been under water.
been under water. Immediately call a qualified
service technician to inspect the fireplace
and replace any part of the control which has
been under water.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Non-combustible materials such as brick and tile can be
extended over the outer face of the unit
extended over the outer face of the unit
(Do not cover
louvres or glass door)
. If a Trim Kit is going to be installed,
brick and tile will have to be installed flush with the side of
this appliance.
this appliance.
FINAL FINISHING
HEARTH
A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a non-combustible
hearth which does not obstruct louvre opening.
aesthetic purposes. We recommend a non-combustible
hearth which does not obstruct louvre opening.
GAS SPECIFICATIONS
MAX.
MIN.
INPUT
INPUT
MODEL
FUEL
GAS CONTROL B.T.U.H
B.T.U.H.
DBR33 RN
Natural Gas
Millivolt Hi/Lo
15,000
10,500
DBR33 RP
Propane Gas
Millivolt Hi/Lo
15,000
11,250
DBR36 RN
Natural Gas
Millivolt Hi/Lo
18,000
12,600
DBR36 RP
Propane Gas
Millivolt Hi/Lo
18,000
13,500
DBR39 RN
Natural Gas
Millivolt Hi/Lo
22,000
15,400
DBR39 RP
Propane Gas
Millivolt Hi/Lo
22,000
16,500
CERTIFIED TO:
ANSI Z1.88b-1999/CSA Z2.33-M-99 harmonized,
standard for Vented Gas Fireplace.
standard for Vented Gas Fireplace.
Table 6
The installation of your Fireplace must
conform with local codes, or in the absence
of local codes, with National Fuel Gas Code,
ANSI Z223.1 — latest edition, or CAN 1 B1-
149.1 and .2 Installation Code. (EXCEPTION:
Do not derate this appliance for altitude.
Maintain the manifold pressure at 3.5 inches
W.C. for Natural Gas and 10 inches W.C. for
LP gas.)
conform with local codes, or in the absence
of local codes, with National Fuel Gas Code,
ANSI Z223.1 — latest edition, or CAN 1 B1-
149.1 and .2 Installation Code. (EXCEPTION:
Do not derate this appliance for altitude.
Maintain the manifold pressure at 3.5 inches
W.C. for Natural Gas and 10 inches W.C. for
LP gas.)
GAS INLET & MANIFOLD PRESSURES
Input Minimum
Input Maximum
Manifold Pressure
NATURAL
LP (Propane)
11" wc
13" wc
10" wc
4.5" wc
7" wc
3.5" wc
Table 7