DV360/580 Series Direct Vent Gas Fireplace
20010667
Instructions for RF Comfort Control Valve
The Comfort Control Valve allows remote control of 
temperature, fan and flame appearance.
NOTE: The antenna should hang in free air away from 
grounded metal.
Operation
1.  If the manual switch is in remote position, switch it to 
LOCAL. (Fig. 60)
2.  Turn the pilotstat knob counterclockwise from OFF 
to the PILOT position, push the knob down, and hold 
in position. The pilot valve opens and allows gas to 
flow to the pilot burner.
3.  Push plunger on the piezo until the pilot burner is lit. 
When the pilot burner is lit, the LED on the control 
will come on after approximately 40 seconds and will 
be continuously red. When the light turns off which 
will be approximately 10 seconds after it has been 
continuously red, the receiver/valve is fully powered.
FP1037
Honeywell 
comfort valve
3/22/00   djt
LOCAL
REMOTE
O
N
PILO
T
OFF
LED
Motor Top Cap
Piezo Ignitor
Local/Remote 
Switch
Pilostat 
Knob
LED
Plug
Antenna
FP1037
Fig. 60  Comfort control valve.
4.  Release the knob. The shaft will move upward. The 
pilot burner should now stay burning. If the pilot 
burner goes out, repeat step 2.
5.  Turn the knob counterclockwise to the ON position. If 
the manual switch is in the LOCAL position, the main 
burner will turn on immediately.
6.  ON the initial use of a transmitter, a recognition 
operation is required between the receiver/valve 
and transmitter. Change the switch from LOCAL 
to REMOTE. Press the fan or flame button on the 
transmitter within 30 seconds. The LED will blink 
indicating the transmitter will now work with the re-
ceiver/valve. If the switch continues in the REMOTE 
position, the transmitter will now control the main 
valve, flame modulation level and fan control.
7.  If the manual switch is in the LOCAL position, the 
valve will be at the highest fixed pressure setting. 
The transmitter will control the fan only.
Shut Off Procedure
If the manual switch is in the REMOTE position, the 
transmitter can shut off the main burner and fan. How-
ever, the control is still on and a command from the 
transmitter can turn on the main burner or fan.
To shut off the system, turn the pilotstat knob clockwise 
to the OFF position. This action closes the main gas 
and safety valves. The transmitter cannot turn on the 
main burner or fan.
Transmitter Operation
Off Mode
In the OFF mode, the fireplace flame and fan are 
off, the display will show OFF and displays the room 
temperature. If the receiver is in REMOTE mode, the 
fireplace will shut off.
FP1039
comfort valve
transmitter
3/27/00   djt
Display
  Room Temperature
  Set Temperature
  Flame Height Level
  Fan Speed Level
  Countdown Timer
  Low Battery
Flame
Up 
 
  Increases  
  Flame Height,  
  Fan Speed  
  Timer or Set  
  Point
Down
  Decreases  
  Flame, Fan  
  Speed Timer or  
  Set Point
Mode
  Auto
  On
  Off
Countdown 
Timer
Fan
FP1039
Fig. 61  Transmitter diagram.
On (Manual) Mode
In the ON mode, the room temperature, flame and fan 
levels will be shown. MANUAL will appear next to both 
the flame and fan icons.
When the control is in the ON mode, the flame and fan 
levels, and delay timer are changed with the up and 
down buttons. To change the flame level, press the 
flame button followed by an arrow key. To change the 
fan level, press the fan key followed by an arrow key. 
Pushing the arrow key once will change the level by 
one unit.