Справочник Пользователя для Vermont Casting DV360

Скачать
Страница из 56
7
DV360/580 Series Direct Vent Gas Fireplace
20010667
Framing And Finishing
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance: Choose the location.
DV360 (Fig. 5)
1.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 1/2” 
drywall while flange “B“ is for 5/8” drywall.
2.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in 
place.
A
B
FP1539
flange location
12/04
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
Flange Location for 
Desired Drywall Depth
FP1539
Fig. 5  Drywall flange location for DV360.
DV580 (Fig. 5a)
1.  Nailing flanges are supplied with the fireplace (found 
on the fireplace hearth). To level the box and secure 
it firmly in place, remove the nailing flanges from 
the hearth and install at the sides of the fireplace as 
shown in Figure 5a.
2.  Screw through the slotted holes in the drywall strip 
and into pre-drilled holes in fireplace side. Measure  
from face of fireplace to the face of the drywall strip 
to confirm the final depth.
Final Finishing
Noncombustible materials such as brick or tile can be 
extended over the edges of the face of the fireplace. 
Do not cover the window frame assembly, any vent, 
louvre assembly top or louvre assembly bottom.
 If 
a Trim Kit is to be installed, brick and tile will have to be 
installed flush with the side of this appliance.
FP1023
side nailing flange
1/27/00  djt
A
B
C
Adjustable Drywall Strip 
(Nailing Flange)
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
 
3/4” / 19 mm
Adjustable 
1/2”, 5/8” & 3/4” 
Spacing
FP1023
Fig. 5a  Adjustable drywall strip (nailing flange) for DV580.
DV360 / DV580
Certified To
ANSI Z21.88-2005 / CSA 2.33-2005 
Vented Gas Fireplace Heater
For units:
GFDN4L2, GFDE4L2, GFDI4L2, GFDL4L2
GFDN4P0, GFDE4P0, GFDI4P0
Gas Specifications
 
 
 
 
MAX. 
MIN.
 
  
 
GAS 
 INPUT   INPUT
  MODEL 
FUEL 
CONTROL 
B.T.U.H  B.T.U.H.
  DV360RN 
Natural Gas 
Millivolt Hi/Lo 
30,000 
18,500
  DV360RP 
Propane 
Millivolt Hi/Lo 
30,000 
17,000
  DV360EN 
Natural Gas 
24 Volt Hi/Lo 
30,000 
18,500
  DV360EP 
Propane 
24 Volt Hi/Lo 
30,000 
20,000
  DV360RFN  Natural Gas  Comfort Control  30,000 
20,000
  DV360RFP 
Propane 
Comfort Control  30,000 
21,000
  DV580RN 
Natural Gas 
Millivolt Hi/Lo 
38,000 
26,500
  DV580RP 
Propane 
Millivolt Hi/Lo 
38,000 
27,000
  DV580EN 
Natural Gas 
24 Volt Hi/Lo 
38,000 
26,500
  DV580EP 
Propane 
24 Volt Hi/Lo 
38,000 
27,000
  DV580RFN  Natural Gas  Comfort Control  38,000 
26,500
  DV580RFP 
Propane 
 Comfort Control  38,000 
27,000
Gas Inlet and Manifold Pressures
   
Natural 
LP (Propane)
  Minimum Inlet Pressure 
5.5” w.c. 
11.0” w.c.
  Maximum Inlet Pressure 
14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.