a
Control select block
A PARA (parallel mode) button
This button lights when Parallel mode is active, 
in which concurrent operation with another 
control panel is possible. When this button is lit, 
all the buttons and controls on this panel except 
for the iris/master black control block are active, 
even if the PANEL ACTIVE button is not lit. If you 
press the button when lit, it goes dark and 
Parallel mode is cancelled.
B MASTER and SLAVE buttons
When adjusting the white balance of multiple 
cameras in Master/Slave mode, designate the 
master camera or the slave cameras. Press and 
light up the MASTER button to specify the 
connected camera for the master. Press and 
light up the SLAVE button to specify the 
connected camera for the slave. The slave 
cameras follow the master camera settings. If 
you press a button when lit, it goes dark.
b
STANDARD button
When you press this button, the video camera is 
initialized to its standard state and the button lights for 
several seconds. If you press the button while it lights, 
the video camera reverts to the state before the button 
was lit.
c
Camera/CCU function ON/OFF buttons
Various functions of the video camera or the CCU/
HDCU-series can be turned on and off from this panel.
5600K
: 5600K -electronic color temperature 
conversion function
AUTO KNEE
: Auto knee function. When this button is 
lit (ON), the knee point is automatically adjusted 
according to the light content of the picture.
SKIN DETAIL
: Skin tone detail function
DTL GATE
: Skin tone detail gate function. When this 
button is lit (ON), the adjustment range of the skin 
tone detail is displayed in white on the PIX (picture) 
monitor screen.
BLACK GAMMA
: Black gamma function
CHARACTER
: Self-diagnostic display function. When 
this button is lit (ON), the contents of the self-
diagnosis of the CCU/HDCU-series are displayed 
on the monitor connected to the CHARACTER 
OUTPUT connector of the CCU/HDCU-series. The 
contents are also mixed to the video signal to be 
output from the PIX1 OUTPUT connector. Each time 
you press this button, the status changes as follows. 
OFF 
t ON (page 1) t ON (page 2) . . .
t ON (page n) t OFF
The contents of the self-diagnosis may be displayed 
when required even if this button is not lit. The right two 
buttons are for future use and do not function at 
present.
d
WHITE (white balance manual adjustment) 
knobs
Used to manually adjust the white balance. From the 
left, the knobs are for R, G, and B signal adjustment.
e
BLACK/FLARE (black balance/flare balance 
manual adjustment) knobs and indicator
Used to manually adjust the black balance (when the 
indicator is not lit) or the flare balance (when the 
indicator is lit). From the left, the knobs are for R, G, 
and B signal adjustment. Selection between black 
balance and flare balance is made using the 
Maintenance menu.
f
Camera number/tally indication window
The number of the camera being controlled from this 
panel is displayed in orange. When a red tally signal is 
sent to the camera, the number is displayed in black 
and the background of the number lights in red.
When a green tally signal is sent to the camera, the 
number is displayed in black and the background of 
the number lights in green. When both the red and 
green tally signals are simultaneously sent, the left half 
of the background lights in red and the right half lights 
in green.
g
ALARM indicator
Lights when trouble occurs in the camera system and 
the self-diagnostic function activates at the video 
camera or the CCU/HDCU-series.
h
CALL button
Press to send a call signal to the video camera, on 
which the CALL button lights. The tally lamps on the 
camera and the red tally lamp on the CCU/HDCU 
Series light when not lit, or go dark when lit. When the 
CALL button on the video camera is pressed, the CALL 
button on this panel lights and a buzzer sounds.
i
PANEL ACTIVE button
Press and light up the button to permit this panel to 
control the camera system (Panel active status). The 
IRIS/MB ACTIVE button also lights. If you press this 
button so that it goes dark, the panel will be locked, 
preventing accidental misoperation.
j
Power and output signal select block
A CAM PW (camera power) button
Press and light up this button to turn the power 
supply to the video camera ON. (The button 
promptly flashes until the camera becomes 
ready for transmission.) When you press this 
button again, it starts flashing and the power 
supply is turned off.
B Signal output select buttons
Press and light up one of these buttons to 
activate the test signal generator of the video 
camera and send the respective signals.
TEST
: To send a signal to test the video circuits
BARS
: To send a color bar signal
Note
The BARS button takes priority to the TEST 
button. If the BARS button is lit, press the button 
to turn it dark before pressing the TEST button.
PARA
MASTER SLAVE
1
2
CHAR
ACTER
5600K
AUTO
KNEE
SKIN
DETAIL
DTL
GATE
BLACK
GAMMA
CAM PW
TEST
BARS
CLOSE
1
2
3