Справочник Пользователя для Vermont Casting 20DVT

Скачать
Страница из 32
10009459
17
Brookhaven Direct Vent Gas Fireplace
Glass Information
Only glass approved by CFM Corporation 
should be used on this fireplace.
• 
The use of any non-approved replacement glass will 
void all product warranties.
• 
Care must be taken to avoid breakage of the glass.
• 
Do not operate appliance with glass front 
removed, cracked or broken.
• 
Replacement glass (complete with gasket and 
window frame) is available through your CFM 
Corporation dealer and should only be installed 
by a licensed qualified service person.
Operating Instructions
Cast Front Panel
Attach the cast 
panel by hook-
ing onto top of 
fireplace.
To remove the 
cast front assem-
bly, pull cast front 
up then lift out.
Glass Cleaning
It is necessary to clean the glass periodically.  During 
start-up condensation, which is normal, forms on the 
inside of the glass and causes lint, dust and other 
airborne particles to cling to the glass surface.  Also 
initial paint curing may deposit a slight film on the glass.  
It is therefore recommended the glass be cleaned 
two or three times with a non-ammonia household 
cleaner and warm water (gas fireplace glass cleaner 
is recommended). After the initial cleaning process the 
glass should be cleaned two or three times during each 
operating season depending on the environment in the 
house.
Clean the glass after the first two weeks of 
operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.
FP1628
Cast front assy
5/06
Cast Front
FP1628
Fig. 29  Remove 
cast front by lifting 
up then out.
Window Frame Assembly Removal
1.  Turn the fireplace OFF (including the pilot).
2.  If the unit has been operating, allow time for the 
components to cool.
3.  Remove cast front assembly.
4.  Unlock the frame window by removing the two (2) 
machine screws at the top corners of the window 
frame.
5.  Unlock the frame window by pulling the handle of the 
two latches at the bottom part of the window frame. 
Pull the left latch counterclockwise and the right 
latch clockwise.
6.  Pull the bottom of the glass frame assembly out and 
slide the top of the frame assembly out the slot at 
the top.
7.  To replace the window frame assembly, reverse this 
procedure.
������
�����������������
����
Machine 
Screw
Machine 
Screw
Pull Left 
Side Latch 
Counter-
clockwise
Pull Right 
Side Latch 
Clockwise
FP1629
Fig. 30  Window frame assembly removal.