ELECTRICAL INSTALLATION
 WARNING: Any electrical re-
wiring of this appliance must be 
done  by  a  qualified  electrician. 
This wiring must be done in ac-
cordance with local codes and/or 
in the U.S.A. with the current, Na-
tional Electrical Code ANSI/NFPA 
No 70 and in Canada with CSA 
C22.1 Canadian Electric code.
This  fireplace  should  be  con-
nected to a dedicated 15 Amp, 
circuit as other appliances may 
cause the circuit breaker to trip 
or fuse to blow when fireplace 
is in operation.
A junction box with universal strain adaptor 
is  provided  to  hard  wire  unit  to  a  15  amp, 
120 Volt 60 Hz grounded circuit. Power cord 
must  first  be  removed  and  universal  strain 
relief bushing inserted into junction box cover 
before connecting supply line (see Figure 7, 
page  5).  If  necessary,  junction  box  may  be 
relocated to route supply to left side.
1.  Remove 2 screws and outer cover on right 
side (see Figure 10).
2.  Remove  inner  screw  securing  junction 
box.
3.  Slide junction box up until mounting tab 
is lined up to notch in outer cabinet.
4.  Swing  box  out  and  slip  retaining  flange 
out through slot in outer cabinet.
5.  Remove 2 screws and outer cover on left 
side  and  reattach  on  right  side  of  outer 
cabinet.
6.  Swing  junction  box  with  harness  to  left 
side while pulling sufficient length of har-
ness out through control panel cover to 
reach mounting location on left side.
7.  Reinsert retaining flange through slot and 
swing screw mounting tab back through 
notch as before.
8.  Slide  junction  box  down  until  mounting 
holes line up and replace inner retaining 
cover.
9.  Pull  end  of  3  wire  Romex  supply  line 
through universal strain relief bushing in 
remaining cover.
10. Strip back outer Romex to about 4” and 
connect black, white and green wires ac-
cordingly using approved connectors. 
11. Tuck  tailing  wires  into  junction  box  and 
replace cover using 2 remaining screws.
12. Tighten  down  strain  adjustment  on  uni-
versal bushing until Romex sheathing is 
secured.
IMPORTANT: Inspect components and wir-
ing for damage before connecting power to 
unit. If any components are found damaged, 
contact an authorized dealer for original DESA 
replacement  part(s)  or  call  DESA  at  1-866-
872-6040 for referral.
IMPORTANT: Prior to operation remove foam 
shipping  brace  located  under  motor  mount 
(see Figure 11, page 7).
Screws
and 
Outer
Cover
Junction Box
Mounting 
Tab
Notch
Retaining 
Flange
Slot
Screws and 
Outer Cover 
from Other Side
Cover with 
Universal 
Strain Relief
Figure 10 - Relocating Junction Box to 
Left
INSTALLATION
Continued
Junction Box