 WARNING: If the area in which 
the heater may be operated does 
not meet the required volume for 
indoor combustion air, combus-
tion and ventilation air shall be 
provided by one of the methods 
described  in  the  National  Fuel 
Gas Code, ANSI Z223.1/NFPA 54, 
the International Fuel Gas Code, 
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building 
This fresh air would come from an adjoining 
unconfined  space.  When  ventilating  to  an 
adjoining unconfined space, you must provide 
two permanent openings: one within 12" of the 
ceiling and one within 12" of the floor on the 
wall connecting the two spaces (see options 
1 and 2, Figure 4). You can also remove door 
into adjoining room (see option 3, Figure 4). 
Follow  the  National  Fuel  Gas  Code, ANSI 
Z223.1/NFPA  54,  Air  for  Combustion  and 
Ventilation
  for  required  size  of  ventilation 
grills or ducts.
aIR FoR CoMBUsTIon and VenTIlaTIon
Continued
Ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation
 for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
Figure 5 - Ventilation Air from Outdoors 
Shown with Optional Mantel
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
Figure 4 - Ventilation Air from Inside 
Building Shown with Optional Mantel
Or  
Remove  
Door into  
Adjoining  
Room,  
Option 3 
Ventilation Grills  
Into Adjoining Room, 
Option 2 
12" 
12" 
Ventilation
Grills into
Adjoining
Room, 
Option 1