USING OPTIONAL AK-4 OUTSIDE AIR KIT
The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside 
combustion air to one side of the fi replace. Use the model AK4 combustion air kit.
MODEL AK-4 COMBUSTION AIR ASSEMBLY
1.  Remove the cover plate from the 4" outlet opening location on the left or 
right outside of the fi replace. 
2.  Place the insulation ring between the AK-4 starting collar and fire-
place wall. 
3.  Place the starting collar (4") into the hole on the side of fi replace. Fasten it in place with the four sheet metal screws 
provided. See Figures 21 and 22.
Note:  The air starting collar extends through the fi replace outer wrap. When the air starting collar is 
securely attached, it will form a seal against the fi replace wall.
4.  Attach outside duct to starting collar with duct clamp or screws. See Figure 22. 
DO NOT remove the 
cover if the outside air 
will not be connected.
W
ARNING
Figure 21 - Attaching Outside Air Starting Collar 
and Insulation Ring to Left Side of Fireplace 
Figure 22- Attaching Outside Duct 
to Starting Collar
Insulation Ring
AK-4 Starting 
Collar 
Sheet 
Meal 
Screws 
Left Side of 
Fireplace 
Shorter End 
of Air Starting 
Collar 
Air Starting 
Collar 
Duct 
Screws 
Left Side of 
Fireplace 
5.  Cut a 6-inch diameter opening for model AK-4 in the outside 
wall covering where the outside vent is to be located. See 
Figure 23.
6.  Select and cut a piece of duct long enough to attach to the 
fi replace and stick out at least 3" beyond the face of the wall 
to which the AK-4 inlet air vent will be attached. See Figure 
22.
Figure 23 - Combustion Air Assembly for 
Model No. AK-4
Nail 
Holes 
Use FP-4 U duct for maximum effi ciency 
and safety. Do not use a combustible 
duct. Always use UL Listed Class 0 or 
1 duct material.
W
ARNING
6" Diameter 
Hole 
Duct 
Extending
3"min. 
AK-4 Inlet 
Air Vent 
Screw
Screws
Continued