360DVS Series Direct Vent Fireplaces
10006326
Glass Cleaning
It is necessary to periodically clean glass. During start-
up, condensation, which is normal, forms on the inside 
of the glass. This condensation causes lint, dust and 
other airborne particles to cling to glass surface.
Also initial paint curing may deposit a slight film on the 
glass. It is therefore recommended glass be cleaned 
two or three times with a non-ammonia based house-
hold cleaner and warm water. The use of fireplace glass 
cleaner is recommended within the first few weeks of 
operation.
After the initial cleaning process the glass should be 
cleaned two or three times during each operating sea-
son depending on the environment in the house.
Clean the glass after the first two weeks of 
operation.
Do not clean the glass when hot.
Do not use an abrasive cleaner.
Do not strike or slam the glass.
Ceramic Refractory Installation
The vertical refractory panels are installed in the unit 
prior to shipment. For assembly procedures, refer to 
Figure 39.
1.  Unpack the ceramic refractory panels from the car-
ton.
Handle the refractory material carefully, the 
panels are fragile.
2.  Place the two end floor refractory panels on the base 
of the fireplace.
3.  Place both side panels along the side of the base.
NOTE:  360DVS2 is the only 360DV unit that is fitted 
with two (2) end vertical panels, as shown in Figure 
39. 360DVSL and 360DVSR units are each fitted 
with one end vertical panel and two side vertical 
panel. The 360DVS3 has only one end vertical 
panel.
FP1446
Cer_refract_panels-designer
360DVS
Vertical Panels in 
Place When Shipped
Floor Panels Placed 
During Installation
Fig. 39  Ceramic panel installation.
FP1446
Log Installation
Refer to Figures 40 and 41 for log location and align-
ment.
Because of the log stack design, these instructions can 
be followed from either side of the fireplace. To follow 
these instructions, identify the logs by the number cast 
into the underside.
For correct operation of the fireplace, the logs must be 
correctly placed in the sequence described below:
1.  Unpack the logs from the shipping carton. The logs 
are fragile; handle them carefully. 
Handle and dispose of plastic bags in 
which logs were shipped in a safe manner. 
As with all plastics, they are not toys and 
should be kept away from infants.
2.  Remove both sides of the window frame assembly 
(where applicable).
3.  Place the log rear (B120) on the grate. The square 
hole located on the underside of the log is to be 
placed over the center of the grate. The inner end 
of the log ensures that the bottom hole is located on 
the pin of the support.
4.  Place the log front left (B121) on the grate. The 
square hole located on the underside of the log is to 
place over the corner leg of the grate. The inner end 
of the log ensures the bottom holes are located on 
the pin of the support.
5.  Place the log front right (B122). Once more, the 
square hole fits over the corner leg of the grate. 
The inner end of this log maintains a recess on the 
underside, which locates over the knob on the top of 
the log front left (B121) to secure the inner end in 
place.
6.  Place the log rear left (B123). The bottom back of 
the log rests on the grate. The notch at the back of 
the log locates over the knob on the top of the log 
rear (B120)
. The bottom of the log rests on top of 
the log front left (B121).
7.  Place the log bottom left (B124). The log maintains 
a step on the outer end, which rests against the 
prong of the grate. The alternate end rests on the 
side floor refractory panel.
8.  Place the log rear right (B125). The log maintains a 
hole on the underside, which rests over the knob on 
the top of the log rear (B120). The bottom of the log 
rests against the side floor refractory panel, and the 
side rests against the last prong of the grate.
9.  Place the log center (B126). The log maintains a 
hole on the underside, which rests over the knob on 
the top of the log front right (B122). The alternate 
end rests against the side floor refractory panel and 