360DVS Series Direct Vent Fireplaces
10006326
Lighting and Operating Instructions
     
 
 
For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
  A.  This fireplace is equipped with an ignition device  
    which automatically lights the pilot. DO NOT try to  
    light the pilot by hand.
  B.  BEFORE OPERATING, smell all around the  
    appliance area for gas. Be sure to smell next to  
    the floor because some gas is heavier than the air  
    and will settle on the floor.
    What to do if you smell gas
    •  Do not try to light any appliance
    •  Do not operate any electrical switch.
    •  Do not use any phone in your building.
    •  Immediately call your gas supplier from a  
      neighbor’s phone. Follow the gas suppliers  
      instructions.
For your safety, read the following warnings  
before lighting the appliance:
  1.  STOP! Read the safety information above before 
continuing.
  2.  Turn off all electrical power to the appliance.
  3.  This appliance is equipped with an ignition device 
which  automatically lights the pilot. DO NOT try to 
light the pilot by hand.
  4.  Access the gas control by lowering the lower 
access door (louvre assembly).
    •  If you cannot contact your gas supplier call  
      the Fire Department
  C. Use only your hand to push in or turn the gas  
    control knob. Never use tools. If the knob will not  
    push in or turn by hand do not try to repair it, call  
    a qualified service technician. Force or attempting  
    repair may result in a fire or explosion.
  D. Do not use this appliance  if any part has been  
    under water. Immediately call a qualified service  
    technician to inspect the appliance and replace  
    any part of the control system and any gas control  
    that has been under water.
1.  Turn the remote switch to the “OFF” position.
2.  Turn OFF all electrical power to the fireplace if 
service is required.
3.  Open the lower access panel.
4.  Turn the shutoff valve on the flexible gas line to the 
“OFF” position.
Warning: If you do not follow these instructions exactly, a fire or explosion may result 
causing property damage, personal injury and loss of life.
Lighting Instructions
Turning Off the Gas to the Appliance
HI
LO
  5.  Turn the remote switch, if used, OFF. Turn the 
wireless remote, if used, OFF.
  6.  Wait five (5) minutes to clear out any gas. Then 
smell for gas, including near the floor. If you smell 
gas STOP. Follow instructions B in the safety 
warnings above. If you do not smell gas go onto the 
next step.
  7.  Close the access door.
  8.  Turn ON all electrical power to the appliance.
  9.  Turn remote switch or wireless remote to ON.
 10.  If the appliance will not operate, follow the 
instructions “Turning Off the Gas to the Appliance” 
(below), and call your service technician or gas 
supplier.
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY 
7/1/98
NOTE:  Shutoff valve  
is shown in “ON” position
1/2” Gas Supply
1/2” NPT x 1/2” Flare 
Shut-Off Valve
3/8” Flex Line
(from valve)