LDVR Series Direct Vent Gas Fireplace
10007317
DVR584-600
Rear vent no elbows
2/99   djt
20" 
(508mm)
Top View
Straight Venting
FP836
Rear Vent-Top View
11/21/98
20"
(508mm)
Max.
REAR VENT-TOP VIEW
20"
(508mm)
Max.
Top View
Rear Vent Corner Installation
Fig. 14  Rear vent applications, one 45° elbow.
45°
45°
Rear Wall Installation
Twist Lock Pipe
STEP 1
Locate vent opening on the wall. To locate hole center 
consult with appropriate fireplace dimensions, Page 4. 
Frame as shown below.
NOTE: When using flex vent, the opening will have to 
be measured according to the 1/2” (13 mm) rise in 12” 
(305 mm) vertical run.
Combustible Walls (Fig. 15)Cut a 10³⁄₈”H x 9³⁄₈” W 
(264 x 240mm) hole through the exterior wall and frame 
as shown. 
Noncombustible Walls (Fig. 15): Hole opening must 
be 7¹⁄₂” (190mm) in diameter. 
STEP 2
Measure wall thickness and cut zero clearance sleeve 
parts to proper length (MAXIMUM 12”/305mm). Assem-
ble sleeve and attach to firestop with #8 sheet metal 
screws (supplied). (Fig. 16)
VO584-100
Vent Opening
2/99   djt
Vent Opening for Combustible Wall
9³⁄₈”
(240mm)
10³⁄₈”
(264mm)
Fireplace Hearth
Framing 
Detail
Opening for Noncombustible Wall
7¹⁄₂”
(190mm)
VO584-100
Fig. 15  Locate vent opening on wall.
ZCS101 
Zero Clearance Sleeve
3/11/99   djt
Max. Length 
12” (305mm)
#8 Screws (2)
#8 Screws 
(2)
Adjustable 
Zero Clearance 
Sleeve
#8 
Screws 
(2)
Adjustable Zero Clearance Sleeve
ZCS101
Fig. 16  Adjustable zero clearance sleeve.
Firestop
STEP 3
Measure from the fireplace collar or elbow face to face 
of outside wall (add 2” for vent pipe overlap). Mark 
pipes and cut to length. It is very important that the two 
pipes are flush with the outside wall once the fireplace 
is in its final location. (Fig. 17)
STEP 4
Slip 4” and 7” pipes onto respective flue collars. Make 
sure to fix to the fireplace collar the 4” pipe with three 
(3) screws before fixing the 7” pipe on the 7” collar. 
Both pipes must be on a level plane. (Fig 18)
STEP 5
Guide the vent termination 4” collar into the 4” pipe then 
the 7” collar into the 7” pipe. Do not force the venting 
into position. If the pipes do not line up with the termi-
nation collars, disassemble pipes and reattach to the 
fireplace collar. (Fig. 18)
STEP 6
Secure fireplace to floor through floor holes and adjust-
able frame drywall strip (nailing flange) to frame. (Refer 
to Framing & Finishing Section).