Справочник Пользователя для Regency P42-LP4

Скачать
Страница из 48
Regency
®
 P42-4 Zero Clearance Direct Vent Gas Fireplace
34
OPTIONAL 
WALL THERMOSTAT 
A wall thermostat may be installed if desired, 
connect the wires as per the wiring diagram. 
Use table below to determine the maximum 
wire length.
Note: Preferable if the thermostat is 
installed on an interior wall.
Regency
®
 offers an optional programmable 
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or 
UL approved may be used.
CAUTION
Do not wire millivolt 
wall thermostat wires
to 120V wire.
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed or with 
broken glass.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
OPERATING INSTRUCTIONS
LIGHTING 
PROCEDURE
NOTE: For all propane units and units    
equipped with electric spark boxes, 
see "Copy of Lighting Plate Instruc-
tions" section for more details.
IMPORTANT: Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
OPTIONAL 
REMOTE CONTROL
Use the Regency
®
 Remote Control Kit  approved 
for this unit. Use of other systems may void 
your warranty.
The remote control kit comes with a hand held 
transmitter, a receiver and a wall mounting 
plate.
1)  Choose a convenient location on the wall 
to install the receiver and the receptacle 
box (protection from extreme heat is very 
important). Run wires from the fi replace to 
that location. Use Thermostat Wire Table.
2)  Connect the two wires to the gas valve. See 
diagram below.
CAUTION
Do not wire millivolt 
remote control wires 
 to 120V wire.
3)  Install 3 AAA alkaline batteries in transmitter 
and 4 AA alkaline batteries in  the receiver. 
Install the receiver and its cover in the wall. 
Switch the  remote receiver to "remote" 
mode. The remote control is now ready for 
operation.
Optional 
WALL SWITCH
1)  Run the supplied 15' of wire through the right 
or left side gas inlet opening. Be careful not 
to damage wire.
Note:  We recommend a maximum of 15' 
of wire but if you wish to go with a 
longer run, use the Thermostat Wire 
Table.
2)  Connect the wire to the supplied wall switch 
and install into the receptacle box.
CAUTION
Do not wire millivolt 
wall switch wire 
to 120V wire.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length 
(Two-Wire) When Using Wall 
Thermostat (CP-2 System)
Wire Size                       Max. Length
Thermostat Wire Table
IMPORTANT
To ignite or reignite the pilot, 
you must fi rst release the 
tension springs below the door.