MAINTENANCE
MAINTENANCE
Power Module
3)  Remove the Control Module by lifting it up 
off of the velcro and pull out.
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Control Module
4)  Remove the Heat Shield from the Control 
Module by removing the 2 screws.
Heat Shield
5)  Unplug all wire harnesses and manual 
control box cable plugged into the Control 
module.
6)  Replace the Control Module and reverse 
steps to re-install. 
CONTROL MODULE 
REPLACEMENT
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Power Module
3)  Remove the Power Module cover by 
removing the 2 screws, one on each side 
of the box.
4)  Replace the 9V and AA battery and reverse 
steps to re-install.
BACKUP BATTERY 
REPLACEMENT
(within Power Module)
NOTE:  The 9V battery operates the 
rear burner under power outage 
conditions.
 
 
The AA battery operates the DC 
Sparker for lighting the pilot.