INSTALLING VALVE
12) Hook up the gas line and check for gas
leaks with a soap and water solution or a
gas leak detector. (Do not use open flame
for leak testing.)
gas leak detector. (Do not use open flame
for leak testing.)
13) Fire up the unit.
14) Check the manifold pressure.
15) Reinstall the vermiculite, embers, rock-
wool and logs as needed.
16) Install and close the door and replace the
louvers.
MAINTENANCE
1) Attach the valve bracket to the valve with
the 4 (m5x8 metric) screws provided.
2) Reconnect the "gas out" 90
o
elbow flare
fitting with an 11/16" wrench.
3) Reconnect the "gas out" flare nut with a
13/16" wrench.
4) Reconnect the quick drop out thermocouple
nut with a 9mm wrench.
5) Reconnect the pilot tube nut with a 7/16"
wrench.
6) Scrape off the old gasket from the floor of
the firebox.
7) Install a new gasket and reinstall the valve
assembly.
Note: Failure to install a new gasket may
severely affect the appliance per-
formance.
formance.
8) Reinstall the 12 hold down screws.
9) Hook up the 2 TP and 2 TH wires to the
appropriate connections on the valve.
10) Reinstall the burner grate. Put a dab of high
temperature silicone over the 3 screw holes.
11) Install Burner tube.