Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
10
B
C
A
FRAMING AND FINISHING
CAUTION:  The  unit  does  not  have  to  be  completely  enclosed  in
a  chase.  The  clearance  on  top  of  the  unit  is  0"  to  the  standoffs
so combustible building materials can be laid directly on top of
the  standoffs.  You  must  maintain    clearance  from  the  flue  to
combustible  materials  for  both  rigid  and  flex,  see  Flue  Clear-
ances,  page  9.
P121 - See Thru
P131 - Pier
Framing Dimensions
     P121 (See Thru)      P131 (Pier)
P121LC / P121RC
(Corner  Unit)
25"(635mm)
  25"(635mm)
26-13/13"(660mm)
minus two times
  minus two times
minus two times
the finishing
  the finishing
the finishing
material thickness*   material thickness* material thickness*
42-1/2"(1080mm)   42-1/2"(1080mm)
42-1/2"(1080mm)
46-3/4"(1187mm)   45" (1143mm)
45"(1143mm)
  minus one time
minus one time
  the finishing
the finishing
  material thickness* material thickness*
Note: These units are
non-load bearing.
P121LC - Corner Unit
* Finish material thickness includes: drywall, ceramic tile, slate, etc.
1) For ease of installation, frame your fireplace after it is positioned and
the flue system is installed. Remember to install the top standoffs.
See page 11 for assembly. Use 2x4's and frame to local building
codes.
2) When locating your appliance on an exterior wall or in a chase, apply
a vapour barrier and drywall, as per local building codes. DO NOT
INSULATE THE FIREPLACE ITSELF.
CAUTION:  Verify  your  fireplace  dimensions,  framing  methods
and  finished  wall  facing  details  before  framing.  Determine  the
total  thickness  of  facing  material  -  drywall  plus  ceramic  tiles,
slate,  etc.  Allow  the  finish  surface  to  be  flush  with  the  front  or
side  of  the  unit.  Total  facing  thickness  can  vary  from  1/2"
(13mm)  to  1-1/4"  (32mm)  thick.
P121RC - Corner Unit
INSTALLATION